06
Case IH 06 – Case Ih Electronic Hitch Control: Slip Control Voltage Low (Short or Open Circuit)
Issue description
The system has detected a low voltage in the slip control circuit, which may be caused by a short or an open circuit. This condition affects the proper operation of the slip control system.
Check the cause
The affected circuit
Connections related to the slip control system
Repair steps
Inspect
Inspect the affected circuit for visible damage, corrosion, or loose connections.
Test
Test the affected circuit for continuity and voltage using a multimeter.
Repair
Repair or replace any damaged components or wiring in the affected circuit.