10

Case IH 10 – Electronic Instrument Cluster (EIC): Memory Retention Error of Battery Calibration Constant

Issue description

The instrument cluster is failing to retain the baseline voltage calibration data in its non-volatile memory, or it is reading a voltage that is drastically out of sync with the actual battery voltage.

Applies to these machines

  • MXM
  • MXM 120
  • MXM 130
  • MXM 140
  • MXM 155
  • MXM 175
  • MXM 190
  • Puma Series

Check the cause

  1. Check battery health to ensure it is fully charged and in good condition, as weak batteries or voltage fluctuations can trigger false ICU memory errors.

  2. Perform a Voltage Comparison Test by turning the key on, navigating the instrument panel display to show system voltage, measuring the voltage directly across the battery terminals with a multimeter, and comparing the two readings.

Repair steps

  1. Evaluate voltage test results

    Evaluate the results of the Voltage Comparison Test.

  2. Check voltage difference

    If the voltage reading on the instrument panel differs from the actual battery voltmeter reading by more than 2.0 volts, the internal memory/calibration of the cluster has failed.

  3. Remove instrument panel

    Remove and replace the instrument panel.

  4. Install new panel

    Install the new instrument panel.

  5. Verify voltage display

    Turn the key start to ON and recheck the voltage display to ensure the new panel is reading the battery voltage correctly. (Note: Disconnecting the battery to attempt a 'hard reset' is generally ineffective for this specific memory retention hardware failure).

Parts you might need

(3)
  • Electronic Instrument Cluster (EIC) / Instrument Panel

    87749731

    Direct replacement for MXM 120-190 series. Verify serial number and cab configuration (analog vs. digital DIC).

  • Electronic Instrument Cluster (EIC) / Instrument Panel

    82031665

    Direct replacement for MXM 120-190 series. Verify serial number and cab configuration (analog vs. digital DIC).

  • Electronic Instrument Cluster (EIC) / Instrument Panel

    82036342

    Direct replacement for MXM 120-190 series. Verify serial number and cab configuration (analog vs. digital DIC).