Case IH 1016 – Hitch Controller / Armrest Controller / PTO Controller / Draft Controller: Not implemented / PTO Switch Open Circuit / L/H Load Sensing Pin Signal Too Low
Issue description
Depending on the module and generation, code 1016 indicates either a 'Not implemented' software glitch in the Hitch Controller, a PTO ON switch wire connection open circuit, or a L/H load sensing pin signal that is too low.
Applies to these machines
4 machines- Magnum
- Case IH Magnum 235 - 340 (Series 4)
- Case IH MX Series
- Case IH TG Series
Check the cause
For 'Not implemented' Hitch code: Connect the CNH Electronic Service Tool (EST) to the diagnostic port and check if the code is Active or Stored/Pending.
For 'Not implemented' Hitch code: Verify the tractor's configuration settings in the AFS Pro display or EST to ensure the Hitch controller is programmed for the exact options physically installed.
For 'Not implemented' Hitch code: Check the CNH portal for any available software updates or service bulletins for the Hitch controller.
For PTO Switch code: Inspect the wiring harness between the Armrest controller and the PTO switch for broken wires or loose pins, and test the PTO ON switch for continuity.
For Load Sensing Pin code: Check the left-hand (L/H) draft/load sensing pin wiring for shorts to ground or open circuits, and back-probe the connector to verify voltage.
Repair steps
Clear the Code
For the 'Not implemented' Hitch Code: Use the CNH EST or the tractor's diagnostic menu to clear the stored 1016 code. Cycle the key power and operate the hitch to see if the code returns.
Reconfigure the Module
If the code returns, navigate to the Hitch controller configuration menu. Re-enter the correct tractor model, transmission type, and hitch options to overwrite any corrupted configuration data.
Flash the ECU
If the configuration is correct but the code persists, use the EST to flash the Hitch controller with the latest OEM software version.
Repair Wiring
For the alternative codes: Repair or replace the damaged wiring harness section between the armrest and PTO.
Replace Components
Replace the faulty PTO switch or L/H load sensing pin if internal continuity fails.
Parts you might need
(2)PTO ON Switch
Fitment: Case IH MX/TG Series Armrest
L/H Draft / Load Sensing Pin
Fitment: Case IH Electronic Draft Control lower link