107

Case IH 107 – Armrest Controller: Aux 5th remote valve control switch (Retract) is failed in the Armrest Controller

Issue description

The system has detected an electrical failure (such as an open circuit, short circuit, or out-of-range voltage) specifically on the "Retract" circuit of the switch that controls the 5th auxiliary hydraulic remote valve.

Applies to these machines

  • Magnum
  • Magnum Series
  • MX Magnum
  • 180
  • 210
  • 240
  • 245
  • 275
  • 290
  • 315
  • Steiger / STX Series
  • STX 430
  • Steiger 500
  • 550
  • Puma Series
  • Maxxum Series
  • TG Series

Check the cause

  1. Inspect the 5th remote valve switch for physical damage, sticking, or debris preventing it from returning to the neutral position.

  2. Test the switch contacts with a multimeter for an open circuit or a short to ground when the switch is pressed into the 'Retract' position.

  3. Inspect the wiring harness connecting the switch to the Armrest Controller, specifically checking Connector C137 for proper seating, bent pins, or corrosion.

  4. Verify that the Armrest Controller is receiving proper power and ground by checking the data bus wires (cavities 4 and 5) and power/ground wires (cavities 11 and 12).

Repair steps

  1. Disconnect Power

    Turn off the tractor and disconnect the battery to prevent electrical shorts during disassembly.

  2. Access the Switch

    Remove the retaining screws and lift the armrest control panel cover to access the underside of the remote valve switches/levers.

  3. Disconnect the Switch

    Unplug the electrical harness connector specifically routed to the 5th remote valve switch.

  4. Replace the Component

    If the switch failed the continuity test, remove the faulty rocker switch or lever assembly from the panel and snap/bolt the new OEM switch into place. If the switch tested fine but the wiring harness is damaged, repair the broken wire or replace the armrest sub-harness. If both the switch and wiring are good, the Armrest Controller itself has an internal failure and must be replaced.

  5. Reassembly

    Reconnect the switch harness, reinstall the armrest panel, and reconnect the battery.

  6. Calibration

    Turn the key on and clear the fault codes. Depending on the tractor model, you may need to navigate to the "Hitch/Remote Menu" on the display to perform an Armrest Controller Calibration so the system recognizes the new switch limits.

Parts you might need

(6)
  • Switch, 5th Remote

    87414463

    5th Remote Valve Switch

  • Rocker Switch

    87486098

    often superseded

  • Armrest Control Switch

    AS164041AP

    Generic Armrest Control Switch

  • Set of Levers

    84235842

    Remote Valve Lever Set (if integrated)

  • Remanufactured Armrest Controller

    84165726R

    for Magnum/Steiger

  • Armrest Controller

    399285A1

    older MX series

Get help to fix this fault by requesting a quote

Browse other Case IH codes