Case IH 1087 – ATC (Advanced Tractor Control) / EDC (Electronic Draft Control): 8 volt reference is above 8.8 volts
Issue description
The 8 volt reference is above 8.8 volts. This is typically a software configuration error where the system is incorrectly configured to look for hitch load pin(s) (draft sensors) on a tractor model that was not manufactured with them.
Applies to these machines
5 machines- Magnum
- Steiger T4B
- Case IH Magnum 235 - 340 (Series 4)
- Case IH Steiger Series (350 to 600 horsepower)
- Case IH MX / TG Series
Check the cause
Verify Machine Equipment: Physically inspect the tractor's 3-point hitch to confirm that hitch load pins (draft pins) are absent from this specific model.
Check System Configuration: Access the tractor's configuration settings to see if the hitch system is erroneously programmed to expect inputs from hitch load pins.
Circuit Testing (If Configuration is Correct): Use a multimeter to test the 8-volt reference circuit at the ATC/EDC module. Check for a short to a higher voltage source (such as the 12V system) that would push the reference voltage above the 8.8V threshold.
Repair steps
Connect diagnostic tool
Connect the Case IH Electronic Service Tool (EST) to the tractor's diagnostic port, or access the onboard display's configuration menu (depending on the model year).
Navigate to configuration
Navigate to the ATC (Advanced Tractor Control) or EDC (Electronic Draft Control) configuration screen.
Locate parameters
Locate the hitch system configuration parameters.
Find sensor setting
Find the setting for "Hitch Load Pins" or "Draft Sensors."
Change parameter
Change the parameter to "Not Installed" or disable the load pin sensor input.
Save settings
Save the new configuration settings to the module.
Cycle ignition
Cycle the tractor's ignition key (turn off, wait 30 seconds, turn back on) to initialize the new configuration.
Clear fault code
Clear the inactive 1087 fault code from the ATC module memory.
Alternative Wiring Repair
If the configuration was already set correctly, trace the 8-volt reference wiring harness. Locate and repair the short-to-power (12V) that is causing the voltage spike, then clear the code.
Parts you might need
(2)ATC Controller / EDC Module
Generic part; exact OEM part numbers depend heavily on the specific tractor serial number.
Hitch Wiring Harness
Generic part; exact OEM part numbers depend heavily on the specific tractor serial number.
Get help to fix this fault by requesting a quote