Case IH 11012 – Transmission Controller (TRANS): Clutch Pedal Position potentiometer voltage is too High
Issue description
The controller is receiving a voltage signal from the clutch pedal position sensor that exceeds the maximum expected threshold. This condition is typically caused by the sensor's signal wire being shorted to a 12-volt power source, shorted to the 5-volt reference line, an open ground circuit, or an internal failure of the potentiometer itself.
Applies to these machines
6 machines- STX Steiger
- Steiger Series
- Puma Series
- Maxxum Series
- MXM Series
- Farmall Series
Check the cause
Inspect the wiring harness and connector at the clutch pedal potentiometer (located beside the clutch pedal in the cab) for visible damage, corrosion, or loose pins.
Use a multimeter to verify the sensor has a solid ground. An open ground will cause the signal voltage to read high.
Disconnect the sensor and turn the key ON. Check the signal wire on the harness side. If it reads high voltage (5V or 12V) while disconnected, there is a short to power in the wiring harness.
If the harness voltages (5V reference, ground, and signal) are correct when disconnected, the potentiometer has failed internally and must be replaced.
Repair steps
Preparation
Turn off the tractor, apply the parking brake, and disconnect the battery to prevent electrical shorts.
Access the Sensor
Locate the clutch pedal position potentiometer, which is mounted directly to the clutch pedal linkage assembly inside the cab.
Removal
Disconnect the electrical harness connector from the sensor. Remove the retaining hardware (typically M5 screws or a snap ring/clip) securing the sensor to the bracket. Carefully detach the rotary linkage/pin connecting the sensor to the pedal and remove the faulty potentiometer.
Installation
Install the new potentiometer, ensuring the rotary linkage is properly aligned with the pedal mechanism so it sweeps the correct range. Secure the mounting hardware and reconnect the electrical harness.
Calibration
Reconnect the battery and turn the key ON. You must perform a transmission clutch calibration procedure using the tractor's display monitor or an EST (Electronic Service Tool). The system needs to relearn the Bottom of Clutch (BOC = 0%) and Top of Clutch (TOC = 100%) positions. Failure to calibrate will result in code 2024 and the tractor will not move.
Parts you might need
(3)Position Sensor
87605247Fits many Maxxum and Puma models
Lift and Clutch Potentiometer
82021036Fits MXM series
Clutch Pedal Potentiometer
82011878