Case IH 11111 – Auxiliary Remote Valve Controller (AUX67 or AUX89): 1st remote TIMER potentiometer is failed low

Issue description

The control module is reading a signal voltage from the 1st remote valve's timer adjustment knob (potentiometer) that is below the minimum acceptable threshold (typically near 0 volts). This condition is usually caused by a short to ground in the signal wire, a loss of the 5V reference voltage (open circuit), or an internal failure of the potentiometer itself.

Applies to these machines

  • STX Steiger
  • Puma Series 115
  • Puma Series 125
  • Puma Series 140
  • Puma Series 155
  • Puma Series 165
  • Puma Series 180
  • Puma Series 195
  • Puma Series 210
  • Puma Series 260
  • Maxxum Series 100
  • Maxxum Series 110
  • Maxxum Series 115
  • Maxxum Series 120
  • Maxxum Series 125
  • Maxxum Series 130
  • Maxxum Series 140
  • MXM / MXU Series
  • Quantum Series
  • TJ Series / Steiger

Check the cause

  1. Visual Inspection: Access the remote valve controls on the armrest console. Inspect the wiring harness and connector at the 1st remote timer potentiometer for pinched wires, corrosion, or backed-out pins.

  2. Reference Voltage Check: Disconnect the potentiometer. Turn the key to the ON position. Use a multimeter to measure the reference voltage pin on the harness side. It should read approximately 5.0V. If it reads 0V, there is an open circuit in the wiring harness between the potentiometer and the AUX controller.

  3. Ground Check: Verify continuity to ground on the ground pin of the harness connector.

  4. Component Test: If the 5V reference and ground are intact, the issue is isolated to the signal wire or the potentiometer. If the signal wire is not shorted to ground, the potentiometer has failed internally and must be replaced.

Repair steps

  1. Power Down

    Turn off the tractor ignition and disconnect the negative battery cable to prevent electrical damage.

  2. Access the Console

    Remove the retaining screws for the MultiControl armrest console cover to access the underside of the remote valve control switches and potentiometers.

  3. Remove the Faulty Potentiometer

    Locate the timer potentiometer for the 1st remote valve. Disconnect its electrical connector.

  4. Dismount

    Remove the knob from the top of the console, then remove the retaining nut or mounting screws holding the potentiometer to the panel. Pull the potentiometer out from the bottom.

  5. Install the New Part

    Insert the new potentiometer into the console, secure it with the retaining nut, and reattach the control knob.

  6. Reconnect

    Plug the electrical connector into the new potentiometer.

  7. Reassemble and Test

    Reinstall the armrest console cover. Reconnect the battery. Turn the key ON and use the tractor's diagnostic display or the Electronic Service Tool (EST) to clear the inactive 11111 fault code. Test the 1st remote timer function to ensure proper operation.

Parts you might need

(1)
  • Remote Valve Potentiometer (Timer / Flow)

    87605247

    Alternative/Superseded Part Numbers: 60717031, 82010303, 82021036, 82033385, 87559692. This is a standardized CNH potentiometer used across the armrest controls for timer and flow settings on Puma, Maxxum, and Quantum series tractors.

Get help to fix this fault by requesting a quote