Case IH 115 – ATC (Automatic Temperature Controller): Evaporator sensor open or shorted to power
Issue description
This code indicates a circuit failure related to the A/C evaporator temperature sensor. The sensor is a thermistor that monitors the temperature of the air conditioning evaporator coil to prevent it from freezing over and to protect the A/C system from damage. The fault triggers when the controller detects that the sensor circuit is either completely open (e.g., a broken wire, unplugged connector, or internally failed sensor) or shorted to a power source (voltage reading is too high).
Applies to these machines
22 machines- STX Steiger
- Magnum 235 - 340 (Series 4)
- MX Magnum series
- TG series
- Puma series
- STX series
- 2144
- 2166
- 2344
- 2366
- 2377
- 2388
- 2577
- 2588
- 5088
- 6088
- 7088
- 2155
- CPX420
- CPX610
- CPX620
- 521G2
Check the cause
Locate the evaporator temperature sensor and check the electrical connector to ensure it is fully seated and free of corrosion
Inspect the wiring harness between the evaporator sensor and the ATC module for pinched wires, chafing, or breaks (open circuit), or exposed wires touching a 12V source (short to power)
Unplug the sensor and use a multimeter to measure its internal resistance. If the multimeter reads 'OL' (out of limits/infinite resistance), the sensor is internally open and must be replaced
With the sensor unplugged and the key ON, check the harness side for reference voltage from the ATC. If voltage is present on the signal return wire, there is a short to power in the harness
Repair steps
Turn off the machine and disconnect the battery
to prevent electrical shorts.
Access the HVAC evaporator core housing
(usually located under the cab roof panel or behind the seat, depending on the machine model).
Locate the evaporator temperature sensor probe
which is inserted directly into the aluminum fins of the evaporator core.
Disconnect the electrical pigtail connector from the sensor
Carefully pull the old sensor probe straight out of the evaporator fins
Be gentle to avoid bending or damaging the delicate fins of the evaporator core.
Insert the new sensor probe into the exact same location in the evaporator fins
Ensure it is seated to the proper depth so it accurately reads the core temperature.
Reconnect the electrical connector
Reassemble the HVAC housing and cab panels
Reconnect the battery, turn the key ON, and clear the fault codes
via the diagnostic menu or scan tool.
Run the machine and turn the A/C on
to verify the compressor engages, the system cools properly, and Fault Code 115 does not return.
Parts you might need
(3)Evaporator Temperature Sensor
184720A2Replaces older part number 184720A1. Fits Case IH Axial-Flow Combines (2144-7088) and Cotton Pickers (2155, CPX series).
Evaporator Temperature Sensor
184720A1Older part number replaced by 184720A2.
Evaporator Sensor
51558009Fits Case IH Wheel Loaders (e.g., 521G2).
Get help to fix this fault by requesting a quote