Case IH 12014 - EPL – EPL (Electronic Park Lock) Controller: Electrical motor short circuit to power supply
Issue description
This code indicates that the electronic parking brake system has detected a short circuit to battery voltage (Vbatt) on Phase A or Phase B of the power stage circuit.
Applies to these machines
11 machines- VESTRUM CVX
- Puma 125 CVX
- Puma 165 CVX
- Puma 180 CVX
- Puma 195 CVX
- Puma 210 CVX
- Puma 225 CVX
- Vestrum 100 CVXDrive
- Vestrum 130 CVXDrive
- Vestrum 100 ActiveDrive
- Vestrum 130 ActiveDrive
Check the cause
Inspect wiring harness and connectors (X012, X036, X121, X745) for a physical short to battery voltage, damage, or corrosion
Verify that the parking brake is correctly adjusted, as incorrect adjustment is a known trigger for this code
Inspect the EPL box for dirt or debris ingress and check if the protective rubber cap is missing
Check for physical interference between the EPL bracket and the fuel pipes, which can cause vibration damage
Repair steps
Resolve Wiring Shorts
If a short to power is found at connectors X012, X036, X121, or X745, repair the damaged wiring harness or replace the affected connector.
Clear Debris & Install Dampers
Clean out any dirt inside the EPL box. If the rubber cap is missing, replace it. If the EPL is rubbing against the fuel lines, install the field-solution damper kit to provide adequate clearance.
Adjust the Parking Brake
Perform a mechanical adjustment of the parking brake to ensure it is within factory specifications.
Software Update
Update the EPL software to Version 3.2 to resolve false self-diagnostic issues that trigger this code.
Replace the EPL Controller
If the wiring is intact, the brake is adjusted, and the software update does not clear the fault, the EPL hardware has failed and the controller must be replaced.
Parts you might need
(2)EPL Controller (Electronic Park Lock Controller)
48165278Used on Vestrum, Steyr Expert, and New Holland T5 models.
EPL Controller (Hardware Module)
91711292Often referenced in service bulletins alongside the Version 3.2 software update.
Get help to fix this fault by requesting a quote