12014 - EPL

Case IH 12014 - EPL – EPL (Electronic Park Lock) Controller: Electrical motor short circuit to power supply

Issue description

This code indicates that the electronic parking brake system has detected a short circuit to battery voltage (Vbatt) on Phase A or Phase B of the power stage circuit.

Applies to these machines

  • VESTRUM CVX
  • Puma 125 CVX
  • Puma 165 CVX
  • Puma 180 CVX
  • Puma 195 CVX
  • Puma 210 CVX
  • Puma 225 CVX
  • Vestrum 100 CVXDrive
  • Vestrum 130 CVXDrive
  • Vestrum 100 ActiveDrive
  • Vestrum 130 ActiveDrive

Check the cause

  1. Inspect wiring harness and connectors (X012, X036, X121, X745) for a physical short to battery voltage, damage, or corrosion

  2. Verify that the parking brake is correctly adjusted, as incorrect adjustment is a known trigger for this code

  3. Inspect the EPL box for dirt or debris ingress and check if the protective rubber cap is missing

  4. Check for physical interference between the EPL bracket and the fuel pipes, which can cause vibration damage

Repair steps

  1. Resolve Wiring Shorts

    If a short to power is found at connectors X012, X036, X121, or X745, repair the damaged wiring harness or replace the affected connector.

  2. Clear Debris & Install Dampers

    Clean out any dirt inside the EPL box. If the rubber cap is missing, replace it. If the EPL is rubbing against the fuel lines, install the field-solution damper kit to provide adequate clearance.

  3. Adjust the Parking Brake

    Perform a mechanical adjustment of the parking brake to ensure it is within factory specifications.

  4. Software Update

    Update the EPL software to Version 3.2 to resolve false self-diagnostic issues that trigger this code.

  5. Replace the EPL Controller

    If the wiring is intact, the brake is adjusted, and the software update does not clear the fault, the EPL hardware has failed and the controller must be replaced.

Parts you might need

(2)
  • EPL Controller (Electronic Park Lock Controller)

    48165278

    Used on Vestrum, Steyr Expert, and New Holland T5 models.

  • EPL Controller (Hardware Module)

    91711292

    Often referenced in service bulletins alongside the Version 3.2 software update.

Get help to fix this fault by requesting a quote

Browse other Case IH codes