Case IH 12043 – INST (Instrumentation Controller) or ICU (Instrument Cluster Unit): Communications Lost with Vehicle Data Bus 1 and ALL other controllers
Issue description
The instrumentation controller has detected that it can no longer communicate with the tractor's CAN Data Bus. The primary failure modes are: 1. The Data Bus is not powered. 2. The Data Bus is shorted. 3. A passive CAN terminator has failed.
Applies to these machines
13 machines- MX Magnum
- STX Steiger
- Magnum Series
- Boxcar Magnums
- 215
- 235
- 245
- 275
- 305
- 340
- TG Series
- Steiger Series
- Puma Series
Check the cause
Inspect CAN Connectors: Check the CAN bus connectors for moisture, dirt buildup, or aging.
Verify Controller Connection: Ensure the instrumentation controller is securely and properly connected to the Data Bus.
Check Bus Power: Verify that the Data Bus is receiving proper voltage and is powered.
Check for Shorts: Test the Data Bus wiring harness to ensure it is not shorted to ground or power.
Test the Passive Terminator: Check the CAN bus terminator resistor to ensure it has not failed (it should typically read 120 Ohms).
Check Controller Function: Verify the overall function of the instrument controller to rule out an internal failure of the cluster itself.
Repair steps
Disconnect battery
Disconnect the battery to ensure safety while working on the electrical system.
Locate components
Locate the CAN bus connectors and the instrumentation controller harness.
Inspect and clean connectors
Disconnect the harnesses and inspect the pins for corrosion, pushed-back pins, or moisture. Clean and dry the connectors if necessary.
Test and replace terminator
Locate the CAN bus passive terminator(s) on the harness. Use a multimeter to measure the resistance across the terminator. If it does not meet the required specification (120 Ohms), replace the terminator.
Inspect and repair wiring
Inspect the wiring harness for chafing or bare wires that could cause a short circuit in the Data Bus. Repair any damaged wiring.
Reconnect and power on
Reconnect all harnesses and power the tractor on.
Replace instrumentation controller
If the code persists and the wiring/terminators are verified good, the instrumentation controller (instrument cluster) has likely failed internally and must be replaced or sent out for remanufacturing.
Parts you might need
(9)Terminal Connector / CAN Bus Terminator Resistor (120 Ohm / 0.5W)
87345428Fits various Case IH models including Maxxum, Farmall, and Puma series.
Instrument Cluster / Dashboard Display
1964859C6Fits Case IH Magnum 7110, 7120, 7130, 7140, 7150, 7210, 7220, 7230, 7240, 7250, 8910, 8920, 8930, 8940, 8950.
Instrument Cluster / Dashboard Display
1964859C5Fits Case IH Magnum 7110-8950 series.
Instrument Cluster / Dashboard Display
1935128C2Fits Case IH Magnum 7110-8950 series.
Instrument Cluster / Dashboard Display
1935110C1Fits Case IH Magnum 7110-8950 series.
Instrument Cluster / Dashboard Display
1935126C1Fits Case IH Magnum 7110-8950 series.
Instrument Cluster / Dashboard Display
A186273Fits Case IH Magnum 7110-8950 series.
Instrument Cluster / Dashboard Display
47622805For Puma 175.
Instrument Cluster / Dashboard Display
47932860For Puma 175.
Get help to fix this fault by requesting a quote