Case IH 13022 - UCM – UCM: Supply voltage 12VT1 - voltage too low
Issue description
This fault code indicates that the control module is detecting that the voltage at the power input rail "12VT1" has dropped below the normal operational limit (typically below 9 Volts).
Applies to these machines
18 machines- VESTRUM CVX
- Puma
- Magnum
- Steiger
- Optum
- Maxxum
- Axial-Flow 7230
- Axial-Flow 8230
- Axial-Flow 9230
- Axial-Flow 7240
- Axial-Flow 8240
- Axial-Flow 9240
- SR Series
- SV Series
- TR Series
- TV Series
- SR175B
- TR270
Check the cause
Verify that the tractor's main battery and alternator voltage are normal (above 11.5V).
Inspect the cab main fuse box and check the specific fuse for the UCM 12VT1 power rail (often a 15A or 30A mini fuse designated as F-030, F-033, or F-305).
Check the UCM Power Relay (often designated as K-002 or K-007) in the fuse panel to ensure it is receiving the command to close and successfully passing voltage.
Inspect the wiring harness between the UCM Power Relay, the fuse, and the UCM for damaged wires, open circuits, or corroded splices (specifically Splice 118 and Splice 119).
Repair steps
Disconnect Power
Turn off the key switch and disconnect the battery ground cable to prevent short circuits during inspection.
Inspect and Replace Fuse
Access the main fuse/relay panel. Locate the fuse for the UCM 12VT1 circuit. If the fuse is blown, replace it with a new fuse of the exact same amperage.
Test/Replace the UCM Power Relay
Remove the UCM Power Relay. Bench test the relay for continuity when energized, or swap it with a known good relay of the same type (like the horn or work light relay). If the relay is faulty, replace it.
Repair Wiring
Reconnect the battery and turn the key ON. Probe the 12VT1 pin at the UCM connector. If the voltage is still below 9V, trace the wire back to the fuse panel. Repair any breaks, chafing, or corroded splices in the harness.
Clear Codes
Reconnect the UCM. Use the Electronic Service Tool (EST) or the machine's onboard "H Menu" diagnostic display to clear the stored 13022 fault code.
Retest
Cycle the key power and operate the machine to confirm the fault code does not return.
Parts you might need
(4)UCM Power Relay (12V, 30A)
84543666Supersedes older part number 82013124. Standard 5-pin micro/mini relay used in the cab fuse box for UCM power.
UCM Power Fuse
8412770830A Green Mini Blade Fuse. Check specific operator's manual for exact amperage.
Universal Control Module (UCM)
51624377For Combines. Only replace if internal failure is proven.
Universal Control Module (UCM)
51690149For Magnum Tractors. Only replace if internal failure is proven.