14021 - ICU

Case IH 14021 - ICU – ICU: Cranking line - shorted to 12V

Issue description

The engine start line (cranking signal) has remained high (receiving 12V) for over 1 minute continuously. The system detects this as an abnormal condition, as the starter should only be engaged momentarily.

Applies to these machines

  • VESTRUM CVX
  • Case IH Puma Series (165, 180, 195, 210, 225 CVX)
  • Case IH Farmall Series (e.g., 115U Pro EP)
  • Case IH Steiger Series
  • Case IH AFX Combines (e.g., AFX8010)

Check the cause

  1. Check the Ignition/Key Switch to ensure it is not mechanically stuck in the 'crank' position or internally shorted, sending a continuous 12V signal.

  2. Test the Starter Motor Relay (X035) for continuity to ensure the internal contacts have not welded/stuck closed, which would keep the cranking line high.

  3. Inspect Connector X005 (connecting Cab Main Harness to Main Frame Harness) for corrosion, water ingress, or bent pins causing a short to power.

  4. Probe the start line circuit at the instrument panel (pin CN1/16) and trace it to the starter relay. Look for chafed insulation or melted wires that are shorting the cranking line directly to a 12V power source.

Repair steps

  1. Disconnect Power

    Disconnect the negative battery cable to prevent accidental engine cranking or electrical damage during the repair.

  2. Isolate the Short

    Disconnect the starter relay and the ignition switch. Use a multimeter to check for continuity to 12V on the cranking signal wire.

  3. Repair Wiring

    If the multimeter shows a short to 12V in the harness, trace the wire through Connector X005. Repair any chafed or melted sections of the wiring harness using heat-shrink tubing and electrical tape, or replace the damaged harness section.

  4. Replace Faulty Components

    If the starter relay is stuck closed (fails to open when power is removed), replace the relay. If the ignition switch continuously outputs 12V on the crank pin when released to the 'ON' position, replace the ignition switch.

  5. Reassemble and Clear Codes

    Reinstall all connectors and relays. Reconnect the battery. Use the electronic service tool (EST) or the dashboard 'H Menu' diagnostic mode to clear the stored 14021 fault code.

  6. Verify Repair

    Start the tractor normally. Verify that the starter disengages when the key is released and ensure the fault code does not return after 1 minute of operation.

Parts you might need

(10)
  • Starter Relay (12V / 35A-40A)

    87522476

    Fits Case IH MX135, 6130, 420, 620, 625, 635, 7088, 7130, 5088, 5130, MX100, MX110, 6088.

  • Starter Relay (12V / 35A-40A)

    83989947

    Fits Case IH CX series, JX series, 5120, 5130, 5140, and various combines.

  • Starter Relay (12V / 35A-40A)

    1987452C1

    Fits Case IH CX series, JX series, 5120, 5130, 5140, and various combines.

  • Starter Relay (12V / 35A-40A)

    82012872

    Fits Case IH CX series, JX series, 5120, 5130, 5140, and various combines.

  • Starter Relay (12V / 35A-40A)

    86400244

    Fits Case IH Compact Tractors D35, D40, D45, DX35, DX40, DX45, Farmall 40/45.

  • Starter Relay (12V / 35A-40A)

    700788A1

    Fits Case IH C / CX McCormick series.

  • Starter Relay (12V / 35A-40A)

    87392809

    Generic Case IH starter relay.

  • Ignition Key Switch

    Specific OEM number depends on the exact tractor model.

  • Connector X005 Components

    DE_HDP24-24-29P

    Use if repairing the harness connector.

  • Connector X005 Components

    DE_HDP26-24-29S

    Use if repairing the harness connector.

Get help to fix this fault by requesting a quote

Browse other Case IH codes