Case IH 141 – TMF (Tractor Multi-Function Controller) or AUX (Auxiliary Valve Controller): Aux 5th Raise Coil solenoid shorted to 12 volts.
Issue description
The controller has detected that the electrical circuit supplying the 'Raise' solenoid on the 5th auxiliary remote valve is receiving a constant 12-volt power supply when it shouldn't be. This is typically caused by a wiring harness short (a bare wire touching a 12V power source) or an internal short within the solenoid coil itself.
Applies to these machines
5 machines- Magnum
- MX Magnum Series
- TG Series
- Puma Series
- STX Steiger Series
Check the cause
Visually inspect the wiring harness running from the TMF/AUX controller to the rear 5th remote valve block for chafed insulation, pinched wires, or melted loom.
Perform a voltage check: Disconnect the electrical connector at the 5th remote 'Raise' solenoid. Turn the key ON. Check the signal wire for 12 volts while the remote lever is in neutral. If 12V is present, the wiring harness is shorted.
Perform a coil resistance test: Measure the resistance (Ohms) across the pins of the disconnected solenoid coil. A reading of near 0 Ohms indicates an internally shorted coil.
Perform a swap test: Swap the 5th 'Raise' solenoid coil with the 4th 'Raise' or 5th 'Lower' coil. If the fault code changes to match the new location, the solenoid is faulty. If it remains 141, the issue is in the harness or controller.
Repair steps
Power Down
Turn off the tractor, remove the key, and disconnect the battery to prevent electrical spikes.
Locate the Valve
Locate the 5th auxiliary remote valve block at the rear of the tractor. Identify the specific solenoid responsible for the 'Raise' function.
Disconnect
Unplug the electrical harness connector from the faulty solenoid.
Remove the Coil
Remove the retaining nut or bolt at the end of the valve stem that holds the solenoid coil in place.
Replace
Slide the old solenoid coil off the proportional valve cartridge. Slide the new OEM replacement coil onto the stem.
Reassemble
Install and tighten the retaining nut to the manufacturer's torque spec (do not overtighten, as this can distort the cartridge). Reconnect the electrical harness.
Clear Codes
Reconnect the battery, start the tractor, and use the tractor's monitor or a diagnostic tool to clear the inactive fault codes. Cycle the 5th remote to verify proper operation.
Harness Repair
If the harness was the issue, splice in a new section of wire using weather-sealed connectors and re-loom the harness to prevent future chafing.
Parts you might need
(6)Remote Valve Solenoid Proportional Valve
278506A1Commonly fits STX and Magnum series
Remote Valve Solenoid Proportional Valve
278506A2Commonly fits STX and Magnum series
Remote Valve Solenoid Proportional Valve
87778144Commonly fits STX and Magnum series
Remote Valve Solenoid Proportional Valve
87354468Commonly fits STX and Magnum series
12V Solenoid Valve
118872A1Commonly fits MX series like MX100-MX170 and 5000 series
Solenoid Valve
180584A1Commonly fits MX80C through MX135
Get help to fix this fault by requesting a quote