Case IH 142 – TMF (Tractor Management Function) or AUX (Auxiliary Valve) / Armrest controller: Aux 5th Raise solenoid failed open or short circuit.
Issue description
The controller is commanding the 5th auxiliary remote hydraulic valve to the "Raise" (or extend) position, but it is not sensing the expected electrical current. The system has detected either an open circuit (such as a broken wire, disconnected plug, or burnt-out internal coil) or a short circuit to ground.
Applies to these machines
6 machines- Magnum
- Case IH MX Magnum Series
- Case IH TG Series
- Case IH STX Steiger Series
- Case IH Puma Series
- Case IH Maxxum Series
Check the cause
Visually inspect the wiring harness and electrical connector at the 5th auxiliary remote valve block (rear of tractor) for chafed wires, corrosion, or backed-out pins.
Perform a resistance test by disconnecting the harness from the 5th Raise solenoid and measuring resistance across the coil's pins (infinite ohms indicates an open circuit, 0 ohms indicates a dead short).
Perform a component swap test by swapping the 5th Raise solenoid coil with a known-good coil from an adjacent valve. If the fault code follows the coil, the coil is bad; if it remains 142, the issue is in the wiring or controller.
Repair steps
Turn off the tractor and disconnect the battery
This prevents electrical spikes to the TMF controller.
Locate the 5th auxiliary remote valve assembly
Located at the rear hydraulic block.
Disconnect the electrical wiring harness connector
Disconnect from the faulty "Raise" solenoid.
Remove the retaining nut or fastener
This secures the solenoid coil to the hydraulic valve stem/cartridge.
Slide the faulty solenoid coil off the valve stem
Note: You generally do not need to open the hydraulic system or drain fluid just to replace the electromagnetic coil.
Clean the valve stem
Remove any dirt or debris.
Slide the new replacement solenoid coil onto the stem
Reinstall and tighten the retaining nut
Caution: Do not overtighten, as this can distort the coil housing and cause premature failure.
Reconnect the electrical harness connector
Reconnect the battery and test
Start the tractor, clear the inactive fault codes via the monitor, and test the 5th remote valve for proper operation.
Parts you might need
(3)Remote Valve Solenoid / Proportional Valve Coil
278506A1Replaces: 87778144, 87354468, 278506A2. Commonly fits STX Steiger series (e.g., STX425).
Remote Valve Solenoid / Proportional Valve Coil
180584A1Replaces: 160180584A1, 190638A1. Commonly fits MX Series (MX80C, MX100, MX120, MX135).
Remote Valve Solenoid / Proportional Valve Coil
118872A1Commonly fits 5100/5200 series and some MX series.