15006

Case IH 15006 – Steering Controller: Split valve Linear Variable Displacement Transducer (LVDT) - open circuit.

Issue description

The control module has lost the electrical signal from the Split Valve LVDT. An open circuit means the electrical path is broken, which is typically caused by a severed wire, an unplugged connector, or an internal failure of the sensor itself.

Applies to these machines

  • Puma/Mid Range Magnum
  • Maxxum
  • Puma series
  • Magnum series
  • Steiger series

Check the cause

  1. Locate the Fast Steer hydraulic valve block (near the steering orbital valve) and inspect the wiring harness leading to the Split Valve LVDT for chafing, rodent damage, or severed wires.

  2. Disconnect the LVDT sensor plug and check for pushed-back pins, corrosion, or moisture ingress inside the connector.

  3. Using a multimeter, check the continuity of the wiring harness from the LVDT connector back to the Steering Controller (KA) pins. Verify that the sensor is receiving its 5V reference and ground.

  4. Measure the resistance across the LVDT sensor pins. If the multimeter reads 'OL' (out of limits/infinite resistance), the sensor has failed internally.

Repair steps

  1. Prepare machine

    Park the tractor on a level surface, turn off the engine, apply the parking brake, and disconnect the battery to prevent short circuits.

  2. Clean area

    Clean the area around the Fast Steer split valve to prevent dirt from entering the hydraulic system.

  3. Repair wiring

    If wiring is faulty: Splice and repair the broken wire using weather-sealed heat shrink connectors, or replace the damaged pigtail connector.

  4. Remove faulty sensor

    If the sensor is faulty: Disconnect the LVDT electrical connector. Remove the retaining fasteners holding the LVDT to the split valve body and carefully extract the sensor.

  5. Install new sensor

    Install the new LVDT sensor, ensuring any O-rings or seals are properly seated, and tighten to OEM torque specifications.

  6. Reconnect components

    Reconnect the electrical harness and reconnect the battery.

  7. Clear fault code

    Connect the Electronic Service Tool (EST) or use the tractor's onboard diagnostic display to clear the 15006 fault code.

  8. Calibrate system

    Because a steering position sensor was replaced, you must run the Fast Steer / Steering Angle calibration procedure via the EST or the tractor's H1 calibration menu to ensure the controller learns the new sensor's base voltage values.

Parts you might need

(1)
  • Split Valve LVDT Sensor (or Fast Steer Valve Assembly)

    Exact LVDT sensor varies depending on the specific tractor family. If the LVDT is not available as a standalone part, the entire Split Valve Solenoid/Sensor Assembly must be ordered.

Get help to fix this fault by requesting a quote