15007

Case IH 15007 – Steering Controller: Split valve LVDT - short circuit

Issue description

The controller detects a short circuit in the Split Valve LVDT sensor's electrical circuit, meaning the voltage signal is out of the expected range (likely shorted to ground or to another voltage source).

Applies to these machines

  • Puma/Mid Range Magnum
  • Maxxum
  • Case IH Puma (140, 165, 180, 195, 210, 225 CVX)
  • Case IH Steiger
  • Case IH Magnum (MX210, MX230, MX255, MX285)
  • Case IH Maxxum series

Check the cause

  1. Inspect the wiring harness running from the Steering Controller to the Split Valve LVDT for chafed wires, melted insulation, or pinched lines

  2. Disconnect the LVDT sensor and check the electrical connectors for water ingress, corrosion, or bent pins

  3. Test the LVDT sensor with a multimeter to determine if the short circuit is internal to the sensor itself

  4. Check for related steering codes (such as 15012 or 15014) that might indicate a mechanical bind

Repair steps

  1. Power down and disconnect battery

    Power down the tractor and disconnect the battery to protect the Steering Controller.

  2. Repair or replace wiring

    If the diagnostic checks reveal damaged wiring, repair or replace the affected section of the steering harness.

  3. Replace Split Valve LVDT

    If the wiring is intact but the sensor is internally shorted, remove the defective Split Valve LVDT from the steering hydraulic valve block and install a new sensor.

  4. Reconnect battery and clear codes

    Reconnect the battery and clear the fault codes.

  5. Recalibrate steering system

    After replacing steering components or sensors, recalibrate the steering system to prevent fault code 15024 (System not calibrated).

Parts you might need

(1)
  • Split Valve LVDT / Divider Valve Position Sensor

Get help to fix this fault by requesting a quote

Browse other Case IH codes