Case IH 152-04 - IMM – IMM: Unexpected CPU reset. Brownout occurred
Issue description
The control module experienced a sudden drop in its power supply voltage (a 'brownout'). Because the voltage fell below the minimum threshold required for stable operation, the module's internal processor (CPU) was forced to unexpectedly reboot to protect itself from data corruption.
Applies to these machines
1 machine- MAGNUM AFS Connect
Check the cause
Verify that the machine's batteries are fully charged and the alternator is outputting the correct voltage under load
Test the power supply and ground circuits going directly to the IMM for high resistance, corroded battery terminals, loose ground straps, or a failing power relay
Inspect the wiring harness connecting to the IMM for chafing, pinched wires, or water intrusion in the connectors that could cause a momentary short to ground
Monitor the voltage at the IMM connector while wiggling the harness to see if the voltage drops intermittently
Parts you might need
(3)Implement Master Module (IMM)
if the module's internal power supply has failed
Main Power Relay / System Relay
Wiring Harness / Pigtail Connector