Case IH 15204 – Steering Valve Controller (SVC): Steering valve controller failure - Software PSM task failure
Issue description
Internal software error where the Program Sequence Monitoring (PSM) task within the steering controller has failed, meaning the software is not executing its programmed operational sequence correctly.
Applies to these machines
4 machines- Steiger T4B
- AFS Connect Magnum Tractors (Models 180, 200, 220, 240, 250, 280, 310, 340, 380)
- Vestrum CVX Series Tractors (Models 100, 110, 120, 130)
- Farmall Tractors (Models 40, 45, 50)
Check the cause
Verify battery voltage to the steering valve controller is within normal operating limits to rule out voltage-induced software glitches
Ensure the controller is online and communicating properly on the CAN bus, and verify there are no duplicate source addresses
Check the current software version of the Steering Valve Controller (SVC) and the Steering Redundant Controller (SRC) using the diagnostic tool
Repair steps
Connect Diagnostic Tool
Hook up the Case IH diagnostic tool to the machine and confirm 15204 is the active code.
Flash/Update Software
Re-flash or update the Steering Valve Controller (SVC) software to the latest version (e.g., version 2.02).
Verify Flash Integrity
Ensure the software flash test and RAM code test pass.
Hardware Replacement
If the software update fails, the RAM test fails, or the 15204 code immediately returns after a successful flash, replace the physical Steering Valve Controller.
Recalibrate
Reload the Advanced Steering Configuration dataset and perform a steering calibration. Clear all fault codes and test drive.
Parts you might need
(3)Steering Valve Controller (SVC) / Advanced Steering Configuration Controller
Hardware part numbers vary strictly by the exact tractor model and chassis break.
SVC update software (version 2.02)
51631896Advanced Steering Configuration controller dataset (version 3.2)
51573865
Get help to fix this fault by requesting a quote