Case IH 15270 – MTA CCM & APH: Flow command crosscheck between the steering valve main and safety controllers failed
Issue description
Indicates a data mismatch, synchronization issue, or communication failure regarding the hydraulic flow command between the primary steering valve controller and the redundant safety controller.
Applies to these machines
4 machines- Steiger T4B
- Farmall 40
- Farmall 45
- Farmall 50
Check the cause
Inspect the wiring harness and connectors between the steering valve main controller and the safety controller for shorts, opens, corrosion, or loose pins.
Verify the CAN bus communication lines between the modules.
Check for any secondary voltage or sensor codes (such as wheel angle or vehicle speed sensor crosscheck faults in the 1527X family) that might be triggering the flow command mismatch.
Repair steps
Repair or replace wiring
Repair or replace any damaged wiring harnesses between the steering valve and the safety controller.
Update software
Verify the software versions on the CCM/APH and update/re-flash them if a software patch is available to resolve the crosscheck sensitivity.
Replace controller
Replace the steering valve or safety controller if the crosscheck failure is determined to be caused by an internal hardware fault.
Parts you might need
(7)Steering Valve
90347744Steering Valve
47403481Steering Valve
47403483GSteering Valve
1994591C4Steering Valve
88107C93Safety Controller
SBA385871240Safety Controller
SBA385871260
Get help to fix this fault by requesting a quote