15311 - AST

Case IH 15311 - AST – Steering Valve Controller (SVC): Incorrect steering valve controller configuration - Auto-calibration configuration

Issue description

Auto-calibration configuration data stored within the steering system is missing, invalid, or corrupted. The controller does not have the correct baseline parameters (such as PWM signal values and wheel angle sensor limits) required to safely operate the automated steering (AccuGuide) system.

Applies to these machines

  • MAXXUM T4E
  • VESTRUM CVX
  • Magnum
  • Steiger
  • Puma
  • Maxxum
  • Farmall
  • 8120
  • 7240
  • 8240
  • 9240

Check the cause

  1. Check for accompanying SVC fault codes (e.g., 15312, 15313, or 15314) that might indicate a hard failure rather than just a calibration issue

  2. Ensure the tractor's hydraulic oil is at normal operating temperature (cold oil will cause the calibration to fail or generate incorrect data)

  3. Verify that the Wheel Angle Sensor (WAS) linkage on the steering axle is intact, not bent, and securely mounted

  4. Ensure the AFS display (e.g., Pro 700 / Pro 1200) and the Nav Controller are properly communicating on the ISOBUS

Repair steps

  1. Preparation

    Drive the machine to a wide-open, flat, and level area. Ensure the hydraulic fluid is at operating temperature.

  2. Access Calibration Menu

    On the AFS Pro 700 / Pro 1200 display, navigate to CALIBRATION > CALIBR.

  3. Rear Wheel / Steered Wheel Position Calibration

    Select the wheel position calibration. Drive the machine perfectly straight. Press 'OK' on the display to save the center position.

  4. Steering Valve Calibration

    Select the Steering Valve Calibration from the menu. Follow the on-screen prompts. The system will automatically command the steering valve to turn the wheels left and right to learn the correct proportional valve (PWM) command values.

  5. Roll Offset Calibration

    Navigate to CALIBRATION > NAV and perform the roll calibration to compensate for any minor variations in the navigation controller's placement (if required).

  6. Verification

    Engage the auto-guidance system on a test swath to ensure the 'GPS - ISO' steering mode activates and the fault code clears.

  7. Dealer Intervention

    If the calibration repeatedly fails to save, the Steering Valve Controller may have an internal EEPROM failure. A dealer will need to use the CNH Electronic Service Tool (EST) to reflash the controller or replace the steering valve assembly.

Parts you might need

(5)
  • AccuGuide Steering Valve / Steering Control Valve

    84198317

    Common on late-model Case IH tractors

  • AccuGuide Steering Valve / Steering Control Valve

    47403487

    Common on late-model Case IH tractors

  • AccuGuide Steering Valve

    87361918
  • AccuGuide Steering Valve

    87315005
  • Steering Valve / Hand Pump

    387550A2

Get help to fix this fault by requesting a quote

Browse other Case IH codes