Case IH 15320 – Steering Valve Controller (Danfoss PVED-CLS): Steering valve controller failure - ground level above upper limit
Issue description
The ground reference voltage for the steering valve controller has floated above the acceptable maximum threshold. This means the controller is experiencing excessive electrical resistance on its ground circuit, a loose ground connection, or a short-to-voltage on the ground line, causing the system to enter a safe state and disable auto-guidance.
Applies to these machines
6 machines- Steiger T4B
- Case IH Magnum series
- Case IH Steiger series
- Case IH Puma series
- Case IH Optum series
- Case IH Farmall models equipped with CVT and auto-steering capabilities
Check the cause
Locate the PVED-CLS controller on the electrohydraulic steering valve block.
Inspect the 12-pin DEUTSCH connector (DT04-12PA-B016) at the PVED-CLS for water ingress, pushed-out pins, or corrosion.
Measure resistance between Pin 2 (Power Ground) / Pin 3 (Sensor Power Ground) and a clean chassis ground (should be near 0 ohms).
Perform a voltage drop test on the ground circuit with the system powered on to check for high resistance.
Ensure all analog steering sensors (e.g., Wheel Angle Sensor) use the dedicated PVED-CLS sensor ground pin, as external grounding can cause offsets.
Inspect main chassis grounds, including the main battery ground cable and cab-to-chassis ground straps.
Repair steps
Disconnect Power
Turn off the machine and disconnect the negative battery terminal to prevent short circuits.
Clean and Secure Chassis Grounds
Trace the ground wires from the steering valve harness to their termination point on the chassis. Remove the ground ring terminals, clean the chassis surface down to bare metal using a wire brush, and reinstall the terminals securely.
Repair Harness
If the multimeter tests revealed high resistance in the harness between the 12-pin connector and the chassis, locate the chafed or corroded section of the wire. Splice in a new section of wire using weather-sealed heat-shrink butt connectors.
Clean the Connector
Apply a high-quality electrical contact cleaner to the 12-pin DEUTSCH connector on the PVED-CLS. Allow it to dry, then apply a small amount of dielectric grease to prevent moisture ingress. Reconnect it securely.
Re-test the System
Reconnect the battery and power up the tractor.
Clear Codes
Use the AFS Pro display or the Electronic Service Tool (EST) to clear the fault code stack.
Module Replacement
If the wiring harness tests perfectly (zero resistance to ground) but the 15320 code immediately returns, the internal ground circuit of the PVED-CLS controller has failed. The steering valve controller/actuator will need to be replaced and recalibrated.
Parts you might need
(5)Danfoss PVED-CLS Actuator
11108702Check the engraved plate on your specific valve for the exact match. Must be flashed and calibrated.
Danfoss PVED-CLS Actuator
11164272Check the engraved plate on your specific valve for the exact match. Must be flashed and calibrated.
Case IH Steering Valve Assembly
47403481Magnum/Puma applications. Must be flashed and calibrated.
Case IH Steering Valve Assembly
87391524Steiger/AccuGuide applications. Must be flashed and calibrated.
Case IH Steering Valve Assembly
87585898CSteiger/AccuGuide applications. Must be flashed and calibrated.
Get help to fix this fault by requesting a quote