15323

Case IH 15323 – PVED-CLS Main and/or Safety Controller: Steering valve controller - Too many errors

Issue description

Triggered when the steering controller logs more than 5 errors simultaneously. Because there are too many errors to handle, the system flags this as a severe internal failure and forces the steering system into a safe state (lockout of electro-hydraulic steering functionality) to prevent erratic or unsafe steering behavior.

Applies to these machines

  • Steiger T4B
  • Steiger / Quadtrac series (e.g., 335, 350, 370, 380, 400, 420, 435, 450, 470, 485, 500, 535, 550, 580, 600, 620)
  • Magnum series
  • Puma series
  • Farmall series (e.g., 40, 45, 50, 115U)
  • Axial-Flow series

Check the cause

  1. Connect a diagnostic tool (Case IH Electronic Service Tool or Danfoss PLUS+1) to read the fault stack and identify underlying root cause codes (e.g., CAN communication loss, sensor voltage drops, or internal buffer overflows)

  2. Check the diagnostic LED on the PVED-CLS module to determine if the Main microcontroller is stuck in bootloader mode or in a severe safe state

  3. Verify power and ground to the controller. Ensure voltage is between 11V and 35.5V, as drops below 9V or erratic power supply can cause multiple simultaneous errors

  4. Inspect the 12-pin Deutsch connector (DT04-12PA-B016) at the PVED-CLS for moisture, corrosion, or backed-out pins

Repair steps

  1. Resolve Root Errors

    Address the specific underlying faults found in the diagnostic stack (e.g., repairing a damaged CAN bus wire or replacing a shorted Wheel Angle Sensor).

  2. Clear and Reset

    Clear the fault codes using the service tool. A hard reset (complete power cycle/battery disconnect) is required to bring the PVED-CLS out of its severe safe state.

  3. Firmware Flash

    If the underlying errors point to a software interpolation overflow or an internal CAN Tx buffer overflow, use the Danfoss PLUS+1 Service Tool to reflash the firmware on both the Main and Safety Controllers.

  4. Replace the Module

    If the module will not accept a flash, the LED remains in a severe fault state, or the internal hardware has failed, replace the PVED-CLS module or the entire steering valve assembly.

  5. Recalibrate

    If the PVED-CLS or steering valve is replaced or flashed, you must perform an Auto Steering Calibration. This includes calibrating the Wheel Angle Sensor (WAS) and the hydraulic spool dead-bands.

Parts you might need

(2)
  • PVED-CLS Steering Controller Module

    51638672

    Manufacturer: Danfoss. Mounts directly to the steering valve. May require programming/parameter setup via PLUS+1 upon installation.

  • Pilot Steering Orbital / EHi Steering Valve Pump Assembly

    87667045

    Replaces older part number 87426127; Casting number 11025446. Primarily fits Steiger, Quadtrac, and STX series tractors.

Get help to fix this fault by requesting a quote