Case IH 15325 – Steering Valve Controller (SVC): Software in the steering valve controller does not match the controller
Issue description
This code indicates a software mismatch or incompatibility between the flashed software and the physical Steering Valve Controller hardware, or a mismatch between the main steering controller and the redundant safety controller.
Applies to these machines
18 machines- Steiger T4B
- AFS Connect Magnum Series 180
- AFS Connect Magnum Series 200
- AFS Connect Magnum Series 220
- AFS Connect Magnum Series 240
- AFS Connect Magnum Series 250
- AFS Connect Magnum Series 280
- AFS Connect Magnum Series 310
- AFS Connect Magnum Series 340
- AFS Connect Magnum Series 380
- Steiger Series
- Vestrum CVX Series 100
- Vestrum CVX Series 110
- Vestrum CVX Series 120
- Vestrum CVX Series 130
- Farmall Series 40
- Farmall Series 45
- Farmall Series 50
Check the cause
Check for accompanying codes, specifically 15326, which confirms a synchronization issue between the main and redundant controllers.
Connect the Case IH Electronic Service Tool (EST) and verify the software identifiers for both the Steering Valve Controller (SVC) and the Steering Redundant Controller (SRC).
Ensure that the physical steering valve controller has not been recently replaced with an incorrect hardware revision that does not support the currently flashed software.
Repair steps
Connect Diagnostic Tool
Connect the Case IH Electronic Service Tool (EST) to the tractor's diagnostic port.
Identify Current Software
Navigate to the Steering Valve Controller (SVC) module and read the current software version and part number.
Flash / Update Software
If the software is corrupted, outdated, or mismatched, use the EST to re-flash the Steering Valve Controller with the correct software payload for your specific PIN/serial number.
Synchronize Controllers
Ensure that the Steering Redundant Controller (SRC) is also flashed with the exact same matching software version to prevent code 15326 from triggering.
Calibrate
After a successful flash, perform the steering valve calibration procedure as prompted by the EST.
Clear Codes
Clear all fault codes, cycle the key off for 30 seconds, and turn it back on to verify that code 15325 does not return.
Hardware Replacement
If the controller refuses to take the flash or the EST indicates a hard internal failure (e.g., EEPROM write failure), the physical Steering Valve Controller must be replaced and then programmed.
Parts you might need
(3)Steering Valve Controller (SVC) Software Payload
51631896Software version 2.02 for AFS Connect Magnum SVC and SRC
Advanced Steering Configuration Controller Dataset
51573865Dataset version 3.2
Steering Valve Controller (Hardware)
Part number varies heavily by specific tractor model and chassis serial number. Must be sourced via the Case IH parts catalog using the machine's exact PIN.
Get help to fix this fault by requesting a quote