Case IH 15336 - AST – Steering Valve Controller (SVC): EEPROM configuration sectors: approval CRC failure
Issue description
This fault indicates that the configuration data stored in the non-volatile memory (EEPROM) of the steering controller has failed its Cyclic Redundancy Check (CRC). The configuration dataset required to operate the advanced steering system is corrupted, missing, or invalid.
Applies to these machines
19 machines- MAXXUM T4E
- VESTRUM CVX
- AFS Connect Magnum 180
- AFS Connect Magnum 200
- AFS Connect Magnum 220
- AFS Connect Magnum 240
- AFS Connect Magnum 250
- AFS Connect Magnum 280
- AFS Connect Magnum 310
- AFS Connect Magnum 340
- AFS Connect Magnum 380
- Vestrum CVX 100
- Vestrum CVX 110
- Vestrum CVX 120
- Vestrum CVX 130
- Farmall 40
- Farmall 45
- Farmall 50
- Farmall 115U
Check the cause
Verify Active Faults: Enter the diagnostic mode by navigating the 'H' menus using the switches on the instrument cluster. Navigate to the R1 module, menu H3, and select the AST system to confirm the active status of the code.
Check Software/Dataset Versions: Using the Case IH Electronic Service Tool (EST), verify the current software and dataset on the Steering Valve Controller. A corrupted dataset is the primary cause of this code.
Inspect Power Supply: Check for recent low battery voltage events, loose grounds, or power interruptions. Voltage drops during an EEPROM write cycle are a common cause of CRC corruption.
Repair steps
Re-flash the Controller
Connect the Case IH EST diagnostic tool to the machine. Attempt to reload/re-flash the Steering Valve Controller (SVC) with the correct Advanced Steering Configuration dataset.
Perform Calibration
If the flash is successful, perform a full steering system calibration. The system will not operate safely until the new EEPROM configuration is calibrated to the machine's specific steering angle sensors.
Replace the Controller
If the EST tool cannot communicate with the module, the flash process fails, or the 15336 code immediately returns after a successful flash and calibration, the physical EEPROM chip inside the controller has failed. The Steering Valve Controller must be replaced.
Parts you might need
(3)Steering Valve Controller (SVC) / Advanced Steering Controller
The physical hardware part number varies heavily depending on the exact tractor model and steering valve block configuration. Always verify the physical hardware part number stamped on the existing PVED-CLS/SVC unit before ordering a replacement.
SVC Software
51631896Version 2.02 (for re-flashing)
Advanced Steering Configuration Dataset
51573865Version 3.2 (for re-flashing)
Get help to fix this fault by requesting a quote