Case IH 15591: Battery Voltage Insufficient for Auxiliary Steering Pump Operation
Issue description
The battery voltage is insufficient to initiate the operation of the auxiliary steering pump. This condition may prevent the proper functioning of the steering system.
Check the cause
Battery voltage level
Battery connections
Auxiliary steering pump power supply circuit
Repair steps
Check battery voltage
Use a multimeter to measure the battery voltage. Ensure it meets the minimum requirement for starting the auxiliary steering pump.
Inspect battery connections
Verify that all battery connections are clean, tight, and free from corrosion.
Test auxiliary steering pump power supply circuit
Check the wiring and circuitry connected to the auxiliary steering pump for any faults or interruptions.