15591

Case IH 15591: Battery Voltage Insufficient for Auxiliary Steering Pump Operation

Issue description

The battery voltage is insufficient to initiate the operation of the auxiliary steering pump. This condition may prevent the proper functioning of the steering system.

Check the cause

  1. Battery voltage level

  2. Battery connections

  3. Auxiliary steering pump power supply circuit

Repair steps

  1. Check battery voltage

    Use a multimeter to measure the battery voltage. Ensure it meets the minimum requirement for starting the auxiliary steering pump.

  2. Inspect battery connections

    Verify that all battery connections are clean, tight, and free from corrosion.

  3. Test auxiliary steering pump power supply circuit

    Check the wiring and circuitry connected to the auxiliary steering pump for any faults or interruptions.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Case IH codes