15939 - 04 - CSM

Case IH 15939 - 04 - CSM – Cab Suspension Module (CSM): Cab suspension left valve - cab suspension left valve voltage low

Issue description

The controller is detecting insufficient voltage on the circuit operating the left cab suspension valve, indicating a voltage that is below normal or shorted to a low source.

Applies to these machines

  • MAGNUM AFS Connect
  • AFS Connect Magnum 180
  • AFS Connect Magnum 200
  • AFS Connect Magnum 220
  • AFS Connect Magnum 240
  • AFS Connect Magnum 250
  • AFS Connect Magnum 280
  • AFS Connect Magnum 310
  • AFS Connect Magnum 340
  • AFS Connect Magnum 380

Check the cause

  1. Check the wiring harness between the Cab Suspension Module (CSM) and the left cab suspension valve for chafing, shorts to ground, or disconnected pins.

Repair steps

  1. Inspect wiring harness

    Perform wiring and voltage checks on the circuit between the Cab Suspension Module (CSM) and the left cab suspension valve.

  2. Repair or replace wiring

    Repair or replace the wiring harness if chafing, shorts to ground, or disconnected pins are found.

  3. Replace valve coil

    If the wiring harness is intact and providing the correct voltage, replace the cab suspension valve coil as it may have failed internally.

Parts you might need

(2)
  • Cab Suspension Valve (Coil)

    51576248
  • Check Valve (Cab Suspension)

    84418724

    9/16'' - 18; 5 psi