16116 - ATC

Case IH 16116 - ATC – ATC (Automatic Temperature Control): Evaporator sensor shorted to ground.

Issue description

The Automatic Temperature Control (ATC) module has detected that the voltage signal from the A/C evaporator temperature sensor has dropped to ground level. This indicates a short circuit to ground, which can be caused by a failed sensor, damaged wiring, or a faulty controller.

Applies to these machines

  • MAXXUM T4E
  • VESTRUM CVX
  • Magnum 235-340 (Series 4)
  • MX Series
  • TG Series
  • STX Series (280-530)
  • Steiger Series (280-535, 380-530)
  • 2144
  • 2166
  • 2188
  • 2344
  • 2366
  • 2377
  • 2388
  • 2577
  • 2588
  • 5088
  • 6088
  • 7088
  • 2155
  • CPX420
  • CPX610
  • CPX620

Check the cause

  1. Inspect the wiring harness between the ATC module and the evaporator temperature sensor for pinched wires, chafing, or damaged insulation that could be shorting the signal wire to chassis ground.

  2. Disconnect the evaporator temperature sensor. If the fault code changes from ATC 116 to ATC 115 (Evaporator sensor open or shorted to power), the wiring is likely intact and the sensor has an internal short.

  3. If the code remains ATC 116 even with the sensor unplugged, check for a short to ground within the wiring harness itself or an internal failure in the ATC module.

Repair steps

  1. Power Down

    Turn off the machine and disconnect the battery ground to prevent electrical spikes.

  2. Locate the Sensor

    Access the HVAC unit (typically located in the cab roof or under the seat, depending on the specific tractor/combine model) and locate the evaporator core. The temperature sensor is mounted directly on or near the evaporator coil to monitor its temperature and prevent freezing.

  3. Remove the Faulty Sensor

    Disconnect the electrical connector from the evaporator temperature sensor and carefully pull/unclip the sensor from the evaporator core housing.

  4. Install the New Sensor

    Insert the replacement sensor into the exact same position on the evaporator core to ensure accurate temperature readings.

  5. Reconnect

    Plug the electrical connector back into the sensor.

  6. Test the System

    Reconnect the battery, turn the ignition on, and clear the fault codes using the machine's diagnostic display. Run the A/C system on "Auto" to verify that the ATC 116 code does not return and the cab cools properly.

Parts you might need

(1)
  • Evaporator Temperature Sensor

    184720A2

    Replaces older part number 184720A1. This specific sensor is widely used across Case IH Axial-Flow Combines and Cotton Pickers to monitor the A/C evaporator coil and protect the system from freezing.

Get help to fix this fault by requesting a quote