17517

Case IH 17517 – Engine Control Unit (ECU): SCR Inducement: Level 1 (Torque reduction), triggered by EGR valve blocked fault

Issue description

The engine's Exhaust Gas Recirculation (EGR) valve is mechanically blocked or stuck. Because the EGR system is critical for emissions control, this blockage triggers the Selective Catalytic Reduction (SCR) system's inducement strategy, forcing the machine into a Level 1 torque reduction (engine derate) to limit emissions.

Applies to these machines

  • Steiger T4B
  • Magnum
  • Steiger
  • Puma
  • Farmall
  • Axial-Flow combines

Check the cause

  1. Inspect the EGR valve for mechanical blockages, such as dirt or heavy carbon buildup on the valve seat, which prevents it from opening or closing properly.

  2. Connect the Electronic Service Tool (EST) to check for any other active urea/DEF system faults that may be contributing to the inducement lock.

Repair steps

  1. Repair the Root Cause

    Clean, repair, or replace the blocked EGR valve to resolve the physical fault.

  2. Connect the EST

    Connect the Electronic Service Tool (EST) to the machine's diagnostic port and turn the key switch to the ON position without starting the engine.

  3. Navigate to Configuration

    In the EST software, navigate to the 'Configuration' icon.

  4. Select Reset Menu

    Select the "Engine Restart Counter Reset / Unlock Inducement" screen.

  5. Configure

    Click "CONFIGURE SELECTED ITEM".

  6. Unlock Inducement

    Click the "RESET ENGINE RESTART COUNTER / UNLOCK INDUCEMENT" button to clear the inducement restart counters and unlock the system.

  7. Verify

    Perform the SCR Fault Repair Verification Test using the EST to confirm the fault is fully resolved before returning the machine to service.