17659 (F-518406-04) - ECU

Case IH 17659 (F-518406-04) - ECU – Engine Control Module (ECM): ECM 12/24 volt actuator supply 8 is shorted to ground

Issue description

The Engine Control Module (ECM) has detected that the voltage on its 8th actuator supply circuit has dropped to zero due to a short circuit to the chassis or ground. The specific output pins for Supply 8 on the ECM are identified as pins 3.45 and 3.46.

Applies to these machines

  • VESTRUM CVX
  • Axial-Flow Combine 6150
  • Axial-Flow Combine 7150
  • Axial-Flow Combine 7240
  • Axial-Flow Combine 7250
  • Axial-Flow Combine 8240
  • Axial-Flow Combine 8250
  • Axial-Flow Combine 9240
  • Axial-Flow Combine 9250
  • Magnum Series
  • Maxxum Series
  • Vestrum Series
  • Luxxum Series
  • Farmlift Series
  • Farmlift 935
  • TC 5.90

Check the cause

  1. Locate the engine harness connector that plugs into the MD1CE101 ECM and identify pins 3.45 and 3.46.

  2. Visually inspect the wiring harness running from these pins to the engine actuators. Look for chafed insulation, pinched wires, or areas where the harness rubs against the engine block or frame.

  3. Disconnect the ECM harness. Using a digital multimeter, measure the resistance between pins 3.45/3.46 on the harness side and a known good chassis ground. If there is continuity, a short to ground is present.

  4. Disconnect the actuators powered by Supply 8 one by one. If the short to ground disappears when a specific actuator is unplugged, that actuator is internally shorted. If the short remains, the wiring harness itself is damaged.

Repair steps

  1. Disconnect Power

    Turn off the machine and disconnect the negative battery terminal to prevent electrical damage.

  2. Access the ECM

    Locate the Bosch MD1CE101 ECM on the engine block or firewall.

  3. Repair the Wiring

    If the diagnostic checks revealed a short in the harness, open the wire loom at the damaged section. Splice and solder the damaged wires for pins 3.45 or 3.46, and seal them with heat-shrink tubing.

  4. Replace Faulty Actuator

    If an actuator was found to be internally shorted to ground during step 4 of the diagnostics, remove and replace the faulty actuator.

  5. Reassemble and Clear Codes

    Reconnect all harness connectors and the battery. Connect a diagnostic tool (such as the CNH Electronic Service Tool (EST) or a compatible scanner like TEXA IDC5) to the machine's OBD/diagnostic port. Clear the inactive fault code 17659 and run the engine to verify the code does not return.

Parts you might need

(3)
  • Engine Control Module (ECM)

    MD1CE101

    The ECM rarely needs replacement for this code unless the internal driver for Supply 8 is permanently burned out.

  • Wiring Harness Repair Kit

    Generic automotive/agricultural 12V/24V wire repair kit (heat shrink, solder, loom).

  • Engine Actuator

    The specific actuator powered by Supply 8 must be identified via the machine's specific wiring schematic if the short is internal to the component.

Get help to fix this fault by requesting a quote

Browse other Case IH codes