18027

Case IH 18027 – Armrest Control Module (ACM): EHR 5 lever position - voltage too low (not applicable to CCM/APH _it may indicate incorrect configuration of the ACM)

Issue description

The system is receiving a voltage signal from the Electro-Hydraulic Remote (EHR) valve lever #5 that has dropped below the minimum acceptable threshold. This could be a false flag caused by an incorrect configuration of the ACM, or if the lever is present, a failed potentiometer, short to ground, or open circuit.

Applies to these machines

  • Magnum
  • Steiger T4B
  • Magnum Series
  • Steiger / Quadtrac Series
  • Puma Series
  • Maxxum Series

Check the cause

  1. Verify ACM Configuration: Check if the tractor actually has a 5th remote lever installed. If not, the ACM is incorrectly configured.

  2. Visual Wiring Inspection: If the 5th lever is present, inspect the wiring harness for pinched wires, chafing, or disconnected plugs causing an open circuit or short to ground.

  3. Swap Test (Component Isolation): Swap the electrical connector of the EHR 5 lever with an adjacent, known-good lever (e.g., EHR 4 or 6). If the fault code changes to the new position, the lever has failed. If it remains 18027, the issue is in the wiring or ACM.

  4. Voltage Test: Use a multimeter to probe the lever's connector to ensure it is receiving the correct 5V reference signal from the ACM.

Repair steps

  1. Power Down

    Turn off the tractor, remove the key, and disconnect the battery ground to prevent electrical spikes.

  2. Access the Armrest

    Remove the retaining screws on the armrest control console to expose the EHR lever bank and the ACM.

  3. Address Configuration (If Applicable)

    If the diagnostic check revealed a configuration error, reconnect power, connect a diagnostic tool (like Jaltest or Case IH EST), navigate to the ACM module, and change the remote valve configuration to the correct number of installed levers.

  4. Replace the Lever (If Faulty)

    Disconnect the wiring harness plug from the bottom of the faulty EHR 5 lever. Remove the mounting hardware securing the lever to the armrest panel. Install the new EHR lever assembly and secure it with the mounting hardware. Reconnect the wiring harness.

  5. Reassembly and Calibration

    Reinstall the armrest console cover. Reconnect the battery.

  6. Calibrate

    Turn the key on and clear the stored fault codes. You must perform an EHR lever calibration procedure (often done via the EIC/display by pressing the CRPM button to access the "R1-R6" menus) so the ACM can learn the new lever's neutral, raise, and lower voltage limits.

Parts you might need

(7)
  • Lever - EHR Black

    47372893R

    EHR Lever Assembly (Joystick/Paddle)

  • Hydraulic Remote Control Valve Lever Assembly

    87687713

    EHR Lever Assembly (includes cable/boot)

  • Lever

    87358094

    EHR Lever Assembly

  • Lever ASS'Y 4 EHR

    90493664

    EHR Lever Assembly

  • Electronic Control Unit for Armrest Control Module

    48068685

    Armrest Control Module (ACM) ECU

  • Module Assy, Armrest Control ACM

    84356319

    Armrest Control Module (ACM) ECU

  • Module Assy, Armrest Control ACM

    48068689

    Armrest Control Module (ACM) ECU

Get help to fix this fault by requesting a quote

Browse other Case IH codes