18311 (518605.02, 518605.07) - ACML

Case IH 18311 (518605.02, 518605.07) - ACML – ACML: EHR1 Program / Motor Mode Switch Error State

Issue description

The control system has detected an invalid signal, switch disagreement, open circuit, or short circuit coming from the switch used to select the operating program or motor mode for the #1 rear hydraulic remote valve.

Applies to these machines

  • MAXXUM T4E
  • VESTRUM CVX
  • Magnum series (235-340)
  • Puma series (165, 180, 195, 210, 225 CVX)
  • Steiger series

Check the cause

  1. Enter the Diagnostic Menu ('H' or 'HJ') on the instrument cluster or AFS display

  2. Monitor Switch Code d95 in the switch testing screen, which identifies the EHR 1 program / motor mode switch

  3. Actuate the EHR1 motor mode switch; the display should show the 'd95' code and emit an audible tone indicating the ACM is receiving the signal

  4. Perform a wiggle test on the wiring harness connecting the switch to the Armrest Control Module if no code is displayed and no tone is heard, to locate intermittent shorts or open circuits

  5. Check for related ACM communication loss codes (such as 2818 or 2819) to rule out a total module failure

Repair steps

  1. Power Down

    Turn off the tractor and disconnect battery power to prevent shorting sensitive CAN-bus components.

  2. Access the Switch Panel

    Disassemble the armrest console / multi-function handle housing to access the rear of the integrated control switch panel.

  3. Inspect Wiring

    Inspect the specific connector and wiring pigtail for the EHR1 switch. Look for backed-out pins, chafed insulation, or corrosion. Repair any harness damage found during the wiggle test.

  4. Test/Replace the Switch

    If the wiring is intact but the switch failed the 'd95' diagnostic test, the switch itself (or the integrated switch module, depending on the exact armrest configuration) has failed internally and must be replaced.

  5. Reassembly & Clearing

    Reassemble the armrest, reconnect the battery, and turn the key on.

  6. Clear Codes & Verify

    Use the Electronic Service Tool (EST) or the onboard display to clear the 18311 / 518605 fault code. Test the EHR1 valve to ensure the motor mode engages properly without throwing a new error.

Parts you might need

(1)
  • EHR Program / Motor Mode Switch (or Integrated Control Switch Panel / Multi-Function Handle Electronic Module)

    Specific standalone part numbers were not isolated; often cataloged as part of the larger Armrest Control Unit or Integrated Control Switch Panel assembly.

Get help to fix this fault by requesting a quote