Case IH 18358 (2660.03, 2660.04) - ACML – ACML: Joystick X-Axis Position ACML - error state
Issue description
Indicates a failure in the signal coming from the X-axis potentiometer or hall-effect sensor of the armrest joystick. The underlying electrical condition is typically a Short to Power (.03) or an Open Circuit / Short to Ground (.04) in the sensor's circuit.
Applies to these machines
6 machines- MAXXUM T4E
- VESTRUM CVX
- Case IH Maxxum series
- Case IH Magnum series
- Case IH Optum series
- Case IH Puma series
Check the cause
Inspect the wiring harness connecting the Multicontroller joystick to the ACML for chafing, pinched wires, or exposed copper.
Check the joystick connector pins for corrosion, moisture, or pushed-out pins.
Test the X-axis sensor circuit for continuity to ground (to rule out an open circuit).
Test the X-axis sensor signal wire for voltage to ensure it is not shorted directly to a 5V or 12V power source.
Repair steps
Replace component
If the wiring harness and connectors test good, replace the faulty joystick component or the ACML itself.
Calibrate module
Perform a software calibration of the new module.