18363

Case IH 18363 – ACML: Joystick Button 10 ACML - error state

Issue description

Indicates a malfunction, electrical short, or communication failure specifically tied to Button 10 on the multifunction joystick.

Applies to these machines

  • VESTRUM CVX
  • Vestrum CVXDrive
  • Steiger series
  • Magnum series

Check the cause

  1. Verify the connections between the multifunction handle and the Armrest Control Module (EHR Control Unit).

  2. Check the current software version of the ACML. Updating to a revised ACML software version with relaxed error code parameters (e.g., increasing error detection time from 50 ms to 500 ms) can resolve false error states.

  3. Use the official Case IH Electronic Service Tool (EST) to read the live data of the joystick buttons if the root cause cannot be found.

Repair steps

  1. Replace components

    Replace the faulty valve controls or the multifunction handle itself if a specific button's internal circuit has failed.

Parts you might need

(2)
  • Multifunction Joystick Handle

    Generic

  • Armrest Control Module / ACML

    Generic

Get help to fix this fault by requesting a quote