Case IH 19 – Central Controller (XCM): Pin Reference Voltage Less Than 8 Volts (Short Or Open Circuit)
Issue description
The 8-volt reference signal supplied to the draft load sensing pins drops below the acceptable threshold. This is typically caused by a short to ground, an open circuit in the wiring harness, a failed load sensing pin, or a failure within the controller itself.
Applies to these machines
40 machines- MXM
- Magnum 7110
- Magnum 7120
- Magnum 7130
- Magnum 7140
- Magnum 7150
- Magnum 7210
- Magnum 7220
- Magnum 7230
- Magnum 7240
- Magnum 7250
- Magnum 8910
- Magnum 8920
- Magnum 8930
- Magnum 8940
- Magnum 8950
- Magnum 9210
- Magnum 9230
- Magnum 9240
- Magnum 9250
- Magnum 9260
- Magnum 9310
- Magnum 9330
- Magnum 9350
- MX80C
- MX90C
- MX100
- MX110
- MX120
- MX135
- MX150
- MX170
- MXM 120
- MXM 130
- MXM 140
- MXM 155
- MXM 175
- MXM 190
- Puma Series
- Magnum 215 through 335
Check the cause
Inspect the central controller (XCM) connectors (C534 and C533) and both load sensing pin connectors (C048 and C047) for damaged pins, corrosion, or a loose fit.
Test the wiring harness for an open circuit or a short to ground between the load sensing pins and the XCM.
Verify that the XCM is outputting the required 8-volt reference signal to the pins.
Isolate the component failure: if the harness and voltage output are good, the load sensing pin has failed internally. If the harness is good but there is no 8V reference, the XCM may be faulty.
Repair steps
Address Wiring
If the diagnostic checks revealed a short or open circuit in the harness, repair or replace the damaged section of the wiring harness.
Bypass the Pins (Recommended)
Locate the two draft load sensing pins on the lower hitch assembly. Unplug the factory wiring harness from both pins. Plug the two electronic load sensing elimination modules directly into the harness connectors. Secure the modules and wiring safely out of the way using tie wraps.
Replace the Pins (Alternative)
Remove the heavy mechanical linkage supporting the lower draft arms, extract the faulty load sensing pin, install the new OEM pin, and reconnect the harness.
Clear Codes
Turn the tractor on and use the diagnostic menu to clear the stored error code 19 from the XCM.
Recalibrate
Perform a hydraulic lift auto-calibration. The system will often throw Code 24 / 1024, which simply means the hydraulic lift calibration must be performed after hitch components or XCM parameters are changed.
Parts you might need
(10)Draft Load Sensing Pin Elimination Kit (Older Magnum / MX Series)
305135A1OEM / Cross-Reference
Draft Load Sensing Pin Elimination Kit (Older Magnum / MX Series)
1964916C3OEM / Cross-Reference
Draft Load Sensing Pin Elimination Kit (Older Magnum / MX Series)
305135A1-KITOEM / Cross-Reference
Draft Load Sensing Pin Elimination Kit (Older Magnum / MX Series)
830485Hy-Capacity
Draft Load Sensing Pin Elimination Kit (Newer Magnum / TG Series)
283771A1OEM / Cross-Reference
Draft Load Sensing Pin Elimination Kit (Newer Magnum / TG Series)
283771A2OEM / Cross-Reference
Draft Load Sensing Pin Elimination Kit (Newer Magnum / TG Series)
87325914OEM / Cross-Reference
Draft Load Sensing Pin Elimination Kit (Newer Magnum / TG Series)
87773863OEM / Cross-Reference
Draft Load Sensing Pin Elimination Kit (Newer Magnum / TG Series)
8302386Hy-Capacity
Hydraulic Load Sensing Pin
1964916C3Direct OEM Replacement
Get help to fix this fault by requesting a quote