Case IH 19059 – Engine Control Unit (ECU): Upstream NOx sensor internal failure (Short Circuit Error)
Issue description
Critical electrical short circuit inside the upstream Nitrogen Oxide (NOx) sensor, which is a key component of the machine's Selective Catalytic Reduction (SCR) and DEF/AdBlue emission control system.
Applies to these machines
18 machines- Tier 4b
- 240 Series Axial-Flow Combines
- 5130
- 6130
- 7130
- 7230
- 8230
- 9230
- 7240
- 8240
- Farmall 100A-170A
- Farmall 115U
- Magnum 180-380
- Maxxum 115-150
- Puma 150-220
- Steiger 350-600
- Titan Floaters 2240-4530
- Patriot Sprayers 2250
Check the cause
Check the operator display for warning symptoms such as 'Engine power loss', 'SCR failure occurring', or a general warning/fault light.
Check for accompanying codes (such as 19060 or 19063) that might indicate broader wiring harness damage rather than an isolated internal sensor failure.
Verify the wiring harness and supply voltage to the sensor plug to confirm the short circuit is internal to the sensor and not a harness issue.
Repair steps
Locate and Remove
Locate the upstream NOx sensor on the exhaust system (positioned before the SCR catalyst) and disconnect it.
Replace
Install the new sensor into the exhaust housing and reconnect the wiring harness.
Clear Codes
After fitting the new NOx sensor, perform an 'error cleaning' using an on-board computer scan or diagnostic tool to clear the DTCs from the ECU so the system recognizes the new sensor.
Parts you might need
(8)Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
84422747Case IH OEM
Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
84422745Case IH OEM
Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
84414466Case IH OEM
Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
47688088Case IH OEM
Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
48011210Case IH OEM
Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
5WK97262Continental cross-reference
Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
5WK96710AContinental cross-reference
Upstream Nitrogen Oxide (NOx) Sensor / DEF Module Sensor
5WK96778Continental cross-reference
Get help to fix this fault by requesting a quote