19196

Case IH 19196 – ECM: Signal range check: low error when heater is Off

Issue description

The system detects a Diagnostic Fault Check (DFC) to Signal Range Check (SRC) Low error on the intake air heater (grid heater) circuit while the heater is commanded OFF. This typically indicates a short to ground, a stuck relay, or a wiring issue causing an unexpected low voltage reading on the power stage of the air heater circuit.

Applies to these machines

  • Tier 4b
  • Puma series
  • Puma 185 CVT
  • Maxxum
  • JX series
  • JX55
  • JX100U
  • N-Series Tractor Loader Backhoes (TLBs)
  • N-Series loaders

Check the cause

  1. Battery Voltage Check: Verify that the system has proper battery voltage, as powerstage diagnosis can be affected by abnormally high or low battery voltage.

  2. Relay Inspection: Test the grid heater power relay. A common failure point on these engines is the grid heater relay sticking closed, which causes a continuous battery draw or circuit error.

  3. Wiring Harness Check: Inspect the grid heater wire harness and relay harness for chafing, melting, or a short circuit to ground.

  4. Heater Element Check: Test the intake manifold air heater element for proper resistance and ensure the terminal posts are not shorting against the intake manifold housing.

Repair steps

  1. Disconnect Power

    Disconnect the negative battery cables to prevent accidental shorts or electrical arcing during the repair.

  2. Locate Components

    Locate the grid heater relay (often mounted near the battery or engine fuse block) and the intake air heater element on the intake manifold.

  3. Remove Faulty Component

    If the relay is stuck closed or failed, unbolt the power cables and remove the relay. If the grid heater element is faulty, remove the intake air horn/cover and extract the heater element.

  4. Install New Parts

    Install the replacement relay or heater element. Crucial Step: When reconnecting the grid heater power cables, ensure that all insulating washers are properly oriented. Failure to install the insulators correctly will cause a dead short to the manifold housing.

  5. Reassemble

    Reinstall any removed intake manifold gaskets or covers. Reconnect the battery terminals.

  6. Clear Codes

    Use the Case IH Electronic Service Tool (EST) to clear the fault code from the ECM, or cycle the ignition to verify the code does not return upon a cold start.

Parts you might need

(9)
  • Grid Heater Power Relay

    47565510

    Case IH / CNH

  • Grid Heater Power Relay

    86619908

    12V, 150A Relay

  • Grid Heater Power Relay

    701637A1
  • Relay Wire Harness

    47679307
  • Power Wire Harness

    47578740
  • Intake Manifold Heater Element

    5161845

    Common on JX series

  • Intake Manifold Heater Element

    893501M1

    Common on JX series

  • Intake Manifold Heater Element

    3118299R1

    Legacy Case IH models

  • Grid Heater Service Kit (Assy)

    718203084

    Tractor Grid Heater Assembly Kit

Get help to fix this fault by requesting a quote

Browse other Case IH codes