19222

Case IH 19222 – Engine Control Module (ECM / ECU): Short circuit to ground on Blow By 3-way valve power stage output

Issue description

The ECU detects that the power supply circuit to the Blow-By valve has shorted to ground. If the blow-by valve is configured to open when de-energized, a short circuit to ground prevents normal operation, and the ECU may be forced to open the main relay (ARly) to ensure the blow-by valve opens, which can affect engine performance or trigger secondary codes.

Applies to these machines

  • Tier 4b
  • Farmall 95U
  • Farmall 105U
  • Farmall 115U Pro
  • Puma
  • Maxxum
  • Magnum
  • Optum
  • N-Series Loader Backhoes
  • 580N

Check the cause

  1. Inspect the wiring harness between the Engine ECU and the Blow-By 3-way valve for chafed insulation, pinched wires, or melted loom that could cause the power wire to touch ground.

  2. Disconnect the plug at the Blow-By valve and the ECU to check for water intrusion, corrosion, or bent pins that could bridge the power circuit to a ground pin.

  3. With the valve disconnected, use a multimeter to check for continuity between the power supply wire in the harness and a known chassis ground (wiring harness short cause).

  4. Test the internal resistance of the Blow-By valve solenoid to see if the internal coil is shorted to its own metal housing (faulty valve cause).

Repair steps

  1. Power Down

    Turn off the machine, remove the key, and disconnect the negative battery cable to prevent ECU damage during electrical work.

  2. Locate the Valve

    Locate the Blow-By 3-way valve. On FPT engines, it is typically mounted on or near the central tappet cover / valve cover.

  3. Repair Wiring

    If the diagnostic tests revealed a short in the harness, splice and repair the damaged section of the wire using heat-shrink connectors, or replace the affected harness section.

  4. Replace the Valve

    Disconnect the electrical connector and the vapor hoses attached to the 3-way valve. Remove the mounting hardware securing the valve to the engine and remove the old valve. Install the new Blow-By valve with a new gasket/O-ring (all gaskets must always be replaced in phase of assembly). Reattach the vapor hoses and tighten the mounting hardware.

  5. Reassembly

    Reconnect the electrical connector to the valve. Reconnect the negative battery cable.

  6. Clear Codes

    Connect the Case IH Electronic Service Tool (EST) or a compatible CAN-bus scanner to clear the inactive 19222 fault code from the ECU memory. Run the engine to verify the code does not return.

Parts you might need

(2)
  • Blow-By Valve / Blow-By 3-Way Valve / Crankcase Ventilation Valve

    504385443

    Verify the part number against the machine's specific Engine Serial Number (ESN) in the CNH parts catalog.

  • Gasket/Seal

    Corresponding replacement gasket/seal for the valve mounting surface.

Get help to fix this fault by requesting a quote