19270

Case IH 19270 – SCR Control Module / Engine Control Unit (ECU): CAN timeout error - CRI1 message

Issue description

The fault is triggered when the ECU experiences a timeout waiting for the CRI1 CAN frame. This means the CAN bus is overloaded, the signal is disturbed, or the frame could simply not be received due to a physical wiring defect or a failed DEF sensor module.

Applies to these machines

  • Tier 4b
  • Magnum
  • Steiger
  • Puma
  • Maxxum
  • Optum
  • Farmall
  • Axial-Flow 7240
  • Axial-Flow 8240
  • Axial-Flow 7150
  • Axial-Flow 8250
  • SV340B
  • TR340

Check the cause

  1. Inspect the CAN bus wiring harness between the DEF Head Unit (Catalyst Reagent Sensor) and the Engine Control Unit / SCR Controller

  2. Disconnect the DEF sensor harness and inspect connectors for damaged wires, pushed-out pins, corrosion, or water ingress

  3. Test CAN bus integrity for a short circuit or physical defect that could cause error frames and high bus load

  4. Verify the DEF sensor unit is receiving proper operating voltage and ground

Repair steps

  1. Disconnect Power

    Turn off the machine and disconnect the battery to prevent electrical spikes.

  2. Repair Wiring

    If the diagnostic checks reveal chafed wires, shorts, or corroded connector pins on the chassis harness leading to the DEF tank, repair or replace the affected pigtail/harness.

  3. Replace the DEF Head Unit

    If the CAN network is intact and communicating properly with all other modules, the internal CAN controller inside the DEF sensor assembly has failed.

  4. Remove the Old Sensor

    Clean the area around the top of the DEF tank to prevent dirt from falling in. Disconnect the electrical connector and the DEF fluid lines. Unbolt/unscrew the DEF head unit from the tank.

  5. Install the New Sensor

    Insert the new combined DEF Level/Temperature/Quality sensor into the tank. Ensure the mounting seal/O-ring is properly seated to prevent leaks. Reconnect the fluid lines and electrical harness.

  6. Clear Codes

    Reconnect the battery, turn the key on, and use a diagnostic tool (like the Case IH EST) to clear the 19270 fault code. Verify that the CRI1 message is now actively broadcasting DEF temperature and quality data to the ECU.

Parts you might need

(7)
  • DEF Quality Sensor / DEF Head Unit

    47520143

    Common on Case IH / New Holland Combines

  • DEF Quality Sensor / DEF Head Unit

    47664489

    Common on Case IH compact track loaders, includes tank mounting seal

  • DEF Head Unit assembly

    KBH17371
  • DEF Quality Sensor / DEF Head Unit

    90454697R

    CNH Remanufactured Option

  • DEF Quality Sensor / DEF Head Unit

    92117978R

    CNH Remanufactured Option

  • DEF Quality Sensor / DEF Head Unit

    47512679R

    CNH Remanufactured Option

  • DEF Quality Sensor / DEF Head Unit

    47512702R

    CNH Remanufactured Option

Get help to fix this fault by requesting a quote

Browse other Case IH codes