1931-02 - UCM

Case IH 1931-02 - UCM – UCM: High temperature in the actuator of rear pilot head #2

Issue description

High temperature in the actuator of rear pilot head #2

Applies to these machines

  • MAGNUM AFS Connect
  • Magnum 400 AFS Connect
  • Optum AFS Connect
  • Steiger AFS Connect

Check the cause

  1. Check the rear pilot head #2 actuator (EHR remote valve actuator) for excessive physical heat.

  2. Inspect the wiring harness and connectors between the UCM and the rear pilot head #2 actuator for shorts, corrosion, or damage that could cause high resistance or false temperature readings.

  3. Ensure the remote valve spool is not mechanically binding, which could cause the actuator to overwork and overheat.

Repair steps

  1. Power down and disconnect battery

    Power down the tractor and disconnect the battery to protect the UCM.

  2. Locate actuator

    Locate the rear pilot head #2 actuator on the rear remote valve stack.

  3. Disconnect harness

    Disconnect the electrical harness from the actuator.

  4. Remove faulty actuator

    Remove the mounting hardware and detach the overheating/faulty actuator from the valve body.

  5. Install replacement actuator

    Install the replacement actuator and reconnect the wiring harness.

  6. Calibrate EHR remote valves

    Power on the tractor and use the AFS Pro 1200 monitor to perform a calibration of the EHR remote valves.

Parts you might need

(1)
  • Rear Pilot Head Actuator / EHR Remote Valve Actuator

    Ensure the replacement actuator is compatible with the specific EHR remote valve stack on AFS Connect models.

Get help to fix this fault by requesting a quote

Browse other Case IH codes