Case IH 19360 – VCM (Vehicle Control Module): Upstream NOx Sensor could not perform self-diagnosis during after run
Issue description
The upstream (inlet) Nitrogen Oxide (NOx) sensor failed to successfully complete its automated self-diagnostic check during the machine's shutdown (after-run) sequence.
Applies to these machines
3 machines- Tier 4b
- Case N-series TLBs (Tractor Loader Backhoes) with Tier 4 Final engines
- CNH equipment using Tier 4 Final VCM architecture
Check the cause
Use the Case IH Electronic Service Tool (EST) to confirm if code 19360 is currently active or just stored in the history.
Check battery voltage, as the VCM will abort the NOx sensor self-diagnosis if the voltage is out of specification (related codes 19361 and 19362 indicate powerstage diagnosis disabled due to high or low battery voltage).
Remove the upstream NOx sensor and inspect the probe tip for excessive Diesel Exhaust Fluid (DEF) crystallization or heavy soot buildup that could blind the sensor.
Repair steps
Remove the Sensor
Disconnect the wiring harness and carefully remove the upstream NOx sensor from the exhaust pipe.
Clean the Probe
If excessive DEF or soot buildup is present, carefully clean the probe area using a soft wire brush. Do not use harsh chemicals or abrasive materials, and do not allow the sensor tip to become wet.
Reinstall and Retest
Reinstall the cleaned sensor. Run the machine and perform a standard shutdown to allow the after-run sequence to initiate.
Replace if Necessary
If the code returns and the sensor still cannot perform its self-diagnosis, the sensor has suffered an internal failure (a common primary failure mode for NOx sensors) and must be replaced.
Clear Codes
Install the new sensor, connect the Case IH EST, and clear the inactive fault codes from the VCM.
Parts you might need
(9)Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
47688088Case IH / CNH OEM Part
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
84422747Case IH / CNH OEM Part
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
84422750Case IH / CNH OEM Part
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
84422745Case IH / CNH OEM Part
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
84292579Case IH / CNH OEM Part
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
5WK97262Continental / VDO manufacturer cross-reference part number
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
5WK96778Continental / VDO manufacturer cross-reference part number
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
5WK96779AContinental / VDO manufacturer cross-reference part number
Upstream NOx Sensor / Inlet Nitrogen Oxide Sensor
5WK96710AContinental / VDO manufacturer cross-reference part number
Get help to fix this fault by requesting a quote