Case IH 19415 (DTC FABF) - ECU – Engine Control Module (ECM) / Dosing Control Unit (DCU): Remaining DEF/AdBlue is below the empty threshold
Issue description
This code indicates that the Diesel Exhaust Fluid (DEF) or AdBlue level in the storage tank has dropped below the minimum allowable limit. When this threshold is breached, the machine's SCR (Selective Catalytic Reduction) system triggers an inducement warning. This will result in an engine power loss (derate) or force the machine into 'creep mode' to prevent the equipment from operating outside of emissions regulations.
Applies to these machines
5 machines- MAXXUM T4E
- 240 Series Axial-Flow Combines (Models 7240, 8240, 9240)
- Magnum Tractors (e.g., 235–340 Series 4)
- Steiger Tractors
- Farmall Tractors
Check the cause
Physical Fluid Check: Visually inspect the DEF/AdBlue tank to confirm if it is actually empty. Do not rely solely on the cab monitor.
Leak Inspection: Check the DEF tank, supply lines, return lines, and fittings for physical damage or fluid leaks.
Sensor Verification: If the tank is full but the code remains active, the DEF level sensor (often part of the DEF header assembly) is likely providing an inaccurate reading due to internal failure, corrosion, or fluid contamination.
Wiring & Harness Check: Inspect the wiring harness and electrical connectors running between the DEF level sensor and the ECM/DCU for corrosion, open circuits, or shorts to ground.
Repair steps
Refill the Tank
Fill the DEF/AdBlue storage tank with high-quality, uncontaminated DEF.
Cycle the Ignition
Turn the key to the ON position and wait for the system to register the new fluid level.
Test the Sensor
If the fluid level does not update on the display, disconnect the DEF level sensor and test the wiring harness.
Replace the Sensor/Header
If the wiring is intact and receiving proper voltage, the DEF level sensor/header has failed and must be replaced. Note: Remove the DEF/AdBlue injector guard and disconnect the electrical connections and fluid lines from the header assembly. Remove the tank cover/header, install the new unit, and reconnect the harness and lines.
Clear Codes & Reset
Clear the fault codes using a diagnostic tool. If the machine was forced into a severe derate or an 'Emergency Re-start' was utilized (which only allows 30 seconds of operation before returning to low idle), the system may require a forced reset or SCR system calibration via the dealer diagnostic tool to restore full engine power.
Parts you might need
(5)DEF Level Sensor / DEF Header Assembly
Generic Name
DEF Level Sensor
47655476Case IH / CNH Industrial
DEF Level Sensor, 70 Micron
47681405Case IH Steiger applications
Remanufactured DEF Sensor
47512679RCase IH Reman
DEF Level Sensor Gasket / Seal
47681396
Get help to fix this fault by requesting a quote