Case IH 1943-08 - UCM – UCM: Rear pilot head #3 failed to initialize
Issue description
A failure of a pilot head to initialize typically indicates a loss of CAN Bus communication or an electrical failure at the remote valve pilot head. When a pilot head fails, it can disrupt the entire CAN Bus network, causing other remote valves to go offline.
Applies to these machines
21 machines- MAGNUM AFS Connect
- Optum 270
- Optum 300
- Puma 185
- Puma 185CVT
- Puma 200
- Puma 220
- Puma 220CVT
- Puma 240CVT
- Steiger 350
- Steiger 400
- Steiger 450
- Steiger 500
- Steiger 580
- Quadtrac 370
- Quadtrac 420
- Quadtrac 450
- Quadtrac 470
- Quadtrac 500
- Magnum 210
- Magnum 280
Check the cause
Unplug the electrical connector to the specific pilot head (#3) to isolate the faulty valve.
Check CAN Bus communication: if unplugging the suspect pilot head causes the rest of the remote valves to come back online, the unplugged pilot head has an internal short or failure that is bringing down the CAN Bus network.
Repair steps
Disconnect harness
Disconnect the electrical harness from the failed pilot head.
Remove valve assembly
Remove the faulty pilot head valve assembly from the remote valve stack.
Install new assembly
Install the new pilot head valve assembly.
Calibrate valves
After installation, the new remote valves must be calibrated via the tractor's display/diagnostic system to ensure proper operation.
Parts you might need
(2)Valve Assy, Pilot Head STD (or Pilot Head Valve Assembly)
47735860Alternative/Superseded OEM Part Numbers: 51456399, 84478197
Hex socket screws (M5 x 20mm, Cl 8.8)
14304324
Get help to fix this fault by requesting a quote