Case IH 1967-04 - UCM – UCM: Rear pilot head #5 reporting supply voltage low
Issue description
The control module is detecting a voltage drop below the operational limit on the circuit supplying power to the 5th rear hydraulic remote valve actuator (pilot head).
Applies to these machines
4 machines- MAGNUM AFS Connect
- Puma
- Magnum
- Steiger
Check the cause
Verify the wiring harness between the UCM and the #5 rear remote pilot head for shorts to ground or broken wires causing the low voltage condition.
Repair steps
Calibrate EHR valves
If a new valve pilot head is installed to correct the fault, an on-board calibration of the rear EHR valves is strictly required.
Access calibration menu
Navigate to the 'H Menu' (HH MENU) on the ADIC dot matrix display and access Channel 1 (Valve Calibration).
Connect tools and complete setup
Connect a pressure transducer and jumper harness to the valve to read calibration data and complete the setup.
Parts you might need
(3)EHR Valve Pilot Head
Generic part name to request from a dealer (also known as Electro-Hydraulic Remote Valve Actuator)
Pressure Transducer
380001903OEM special tool required for calibration
Jumper Harness
84148258OEM special tool required for calibration