Case IH 19684 – Engine Control Module (ECM) or Dosing Control Unit (DCU) / SCR Controller: Error set in case of leak test stopped because of break-off conditions
Issue description
The Selective Catalytic Reduction (SCR) / Diesel Exhaust Fluid (DEF) dosing system leak test (pressure test or purge cycle) was aborted prematurely. This is most commonly caused by operator error (turning off the battery disconnect too soon), electrical interruption, hydraulic failure (massive pressure drop), or extreme temperatures (frozen DEF).
Applies to these machines
9 machines- Tier 4b
- Steiger series (370, 420, 470, 500, 540, 580, 620)
- Magnum series (180, 200, 250, 340, 380)
- Puma
- Maxxum
- Optum series
- Axial-Flow series (5150, 6140, 7140, 7240, 8240, 9240, 7250, 8250, 9250)
- Patriot (4440)
- Titan (3040, 3540, 4040, 4540)
Check the cause
Verify operator shutdown procedure (ensure they wait at least 2 minutes before hitting the battery disconnect switch)
Inspect wiring harness, relays, and fuses supplying power to the DEF Supply Module and DCU for loose grounds or chafed wires
Check DEF tank level, DEF lines, and dosing injector for massive external leaks or heavy white crystallization
Use a diagnostic tool to verify the DEF tank temperature sensor is not falsely reading freezing temperatures
Repair steps
Clear fault code
Connect the CNH Electronic Service Tool (EST) and clear the fault code.
Prime DEF system
Turn the key ON and start the engine to allow the DEF system to prime and build pressure.
Perform shutdown procedure
Turn the key OFF and wait. Listen for the DEF pump running backward. Do not turn off the battery disconnect until the pump completely stops.
Command leak test
If the code returns without operator interruption, use the EST to manually command a DEF system leak test.
Monitor DEF pressure
Monitor the DEF pressure during the test. If the pressure drops suddenly or fails to build, inspect the lines.
Replace DEF Supply Module
If the lines are intact and electrical power is stable, the DEF Supply Module (pump) is failing internally and must be replaced.
Replace DEF main filter
Whenever replacing the DEF pump, or if contamination is suspected, replace the DEF main filter.
Parts you might need
(13)DEF Supply Module (Dosing Pump)
5802855463OEM Part Number
DEF Supply Module (Dosing Pump)
47565939OEM Part Number
DEF Supply Module (Dosing Pump)
5802698300OEM Part Number
DEF Supply Module (Dosing Pump)
47565934OEM Part Number
DEF Supply Module (Dosing Pump)
5802513621OEM Part Number
DEF Supply Module (Dosing Pump)
0444042256Bosch Ref (Denoxtronic 2.2 / 3.1)
DEF Supply Module (Dosing Pump)
0444042210Bosch Ref (Denoxtronic 2.2 / 3.1)
DEF Filter / Service Kit
4765182470-micron OEM Part Number
DEF Filter / Service Kit
47748585OEM Part Number
DEF Filter / Service Kit
47364243OEM Part Number
DEF Filter / Service Kit
84254852OEM Part Number
DEF Filter / Service Kit
UF103Fleetguard Aftermarket Equivalent
DEF Filter / Service Kit
P956170Donaldson Aftermarket Equivalent
Get help to fix this fault by requesting a quote