Case IH 19739 – DCU or ECM / PCM: Main Relay opens too early / too late | main relay shut off too late | P0687 ECM/PCM Power Relay Control Circuit High
Issue description
Malfunction in the ECM/PCM power relay control circuit. The system detects that the main power relay is opening too early or shutting off too late (sticking closed), indicating a high value in the power relay control loop.
Applies to these machines
5 machines- Tier 4a
- Case IH Magnum Series (e.g., 235-340 Series 4)
- Case IH STX Steiger Tractors (350 to 600 HP)
- Case IH Puma Series
- Case IH Maxxum and MX series
Check the cause
Verify that battery voltage to the ECM/DCU is within the normal operating range, as voltage spikes or drops can cause relay timing faults.
Swap the Main Power Relay with a known good relay of the exact same amperage and pin configuration (e.g., horn or work light relay) to see if the fault clears.
Check the control loop of the ECM/PCM power relay for a short to ground or short to battery.
Test the relay socket for proper ground and command voltage from the ECM/DCU when the key is cycled.
Inspect the wiring harness between the main relay panel and the ECM/DCU for chafing, corrosion, or open circuits.
Repair steps
Disconnect Power
Turn off the machine and disconnect the negative battery cable to prevent electrical spikes.
Access the Relay Panel
Open the main fuse and relay center (location varies by model, often in the cab headliner, right-hand console, or engine firewall).
Remove the Faulty Relay
Pull the main ECM/DCU power relay. Inspect the spade terminals on the relay and the socket for signs of arcing, melting, or green corrosion.
Clean Contacts
If mild corrosion is present, clean the socket terminals with electrical contact cleaner and a terminal brush.
Replace the Relay
If the relay was sticking closed (causing the 'shut off too late' condition), install a new OEM replacement relay.
Repair Wiring
If the socket tested bad for continuity during diagnostics, trace the wire back to the ECM/DCU and repair the open/shorted section using weather-sealed splice connectors.
Reassemble and Clear Codes
Reconnect the battery, turn the key to the ON position, and use a diagnostic scan tool to clear the 19739 / P0687 / P0685 codes. Cycle the key to verify the code does not return.
Parts you might need
(6)5-Pin 12V Relay
87696396Common on Magnum and Steiger models
12V Electrical Relay
8769639512V, 50A-70A Sealed Relay
84271717Used for heavy-duty main power applications
20 AMP Relay Switch
87414866Common on TG/T8000 series and Steigers
Main Current Relay
198161A1Bosch equivalent: 0986AH0811
ECM/PCM Power Relay / DCU Main Relay
Generic Part Name
Get help to fix this fault by requesting a quote