Case IH 19757 – DCU (Dosing Control Unit): Reagent Pump Not Delivering / Compressed Air Regulation Valve
Issue description
19757 (P208B): The system has detected that the DEF (Diesel Exhaust Fluid / Urea) supply module/pump is failing to build pressure or deliver fluid to the dosing injector. 19766 (P20A7): The system has detected an electrical or mechanical fault in the compressed air regulation valve, which is responsible for managing the air pressure used to atomize the DEF fluid.
Applies to these machines
4 machines- Tier 4a
- Case IH Magnum: 235, 260, 290, 315, 340 (Series 4)
- Case IH Steiger & Quadtrac: 350, 400, 450, 500, 550, 600
- Case IH Rowtrac: 350, 400, 450, 500
Check the cause
For 19757 (P208B - Reagent Pump): Verify the DEF tank is not empty and that the fluid is not degraded or crystallized.
For 19757 (P208B - Reagent Pump): Check the DEF suction and pressure lines for kinks, blockages, or severe leaks.
For 19757 (P208B - Reagent Pump): Inspect the wiring harness connecting the DCU to the DEF pump. Look for damaged wires, loose connector pins, or corrosion (especially from pressure washing).
For 19757 (P208B - Reagent Pump): Check the DEF pump main filter for severe clogging or crystallization.
For 19766 (P20A7 - Air Regulation Valve): Verify that the tractor's pneumatic system is generating and holding adequate air pressure.
For 19766 (P20A7 - Air Regulation Valve): Check the electrical connector at the air regulation valve for a short to ground, short to battery, or open circuit. Ensure the pins are tight and free of moisture.
For 19766 (P20A7 - Air Regulation Valve): Listen and inspect for compressed air leaks between the air supply tank, the regulation valve, and the dosing nozzle.
Repair steps
Clear and Retest
Connect the CNH Electronic Service Tool (EST). Clear the inactive codes and run the engine to operating temperature to see if the fault returns as active.
Harness Repair
If continuity tests reveal a short or open circuit in the wiring to either the pump or the valve, repair the damaged section of the harness or replace the connector pigtail.
Component Replacement
If diagnosing 19757 and the wiring/lines are good, replace the DEF Reagent Pump (Supply Module) and its internal filter. If diagnosing 19766 and the wiring/air supply are good, replace the Compressed Air Regulation Valve.
System Bleed and Test
After replacing SCR components, use the EST to run a "System Leakage Test" and a "Dosing Test" to prime the system, verify that the pump builds pressure, and ensure the air valve atomizes the fluid correctly.
Final Validation
Clear all DCU/ECU fault codes and operate the machine under load to ensure the SCR system is functioning and no codes return.
Parts you might need
(3)DEF Reagent Pump / Supply Module
Generic Fitment: Bosch Denoxtronic Supply Module for CNH
DEF Pump Filter Kit
Highly recommended to replace if servicing the pump
Compressed Air Regulation Valve
Generic Fitment: CNH SCR Air Solenoid/Valve
Get help to fix this fault by requesting a quote