Case IH 1979-04 - UCM – UCM: Rear pilot head #6 reporting supply voltage low
Issue description
While 1979-04 is not a valid code, an actual UCM low voltage fault (like 1902) means the Universal Control Module is receiving insufficient voltage to operate correctly. This is typically caused by a dying battery, a failing battery disconnect switch, or poor ground connections.
Applies to these machines
5 machines- MAGNUM AFS Connect
- Alpha Series skid steers
- B Series skid steers
- TV450B
- compact track loaders
Check the cause
Test the main battery voltage. A reading of 10.99V or lower is insufficient and will trigger UCM voltage faults.
Inspect the battery disconnect/kill switch for loose terminals or internal faults. Bypassing the switch temporarily can help determine if it is the source of the voltage drop.
Check the UCM power supply circuits and ground connections for shorts or open circuits.
Repair steps
Test battery voltage
Disconnect the battery and test its resting voltage.
Clean and tighten terminals
Clean and tighten all battery terminals.
Inspect battery disconnect switch
Inspect the battery disconnect switch. If the switch is faulty, remove the cables and place them together on a single bolt to bypass the switch, or replace the switch entirely.
Reconnect battery and verify
Reconnect the battery and verify that the UCM supply voltage fault codes have cleared.
Parts you might need
(3)12V Heavy-Duty Equipment Battery
Master Battery Disconnect / Kill Switch
Universal Control Module (UCM)
Get help to fix this fault by requesting a quote