Case IH 19817 – Engine Control Unit (ECU) / Dosing Control Unit (DCU): Plausibility of UDV (Urea Dosing Valve) stuck - Reagent dosing valve - blocked (only stuck closed)
Issue description
The NOx neutralization node (DEF power module) has detected that the DEF/AdBlue fluid pressure has exceeded 6.5 bar (650 kPa) for 30 seconds. This overpressure condition indicates that the dosing valve is physically blocked or stuck in the closed position.
Applies to these machines
38 machines- Tier 4a
- Tier 4b
- Magnum 180
- Magnum 200
- Magnum 220
- Magnum 235
- Magnum 240
- Magnum 250
- Magnum 260
- Magnum 280
- Magnum 290
- Magnum 310
- Magnum 315
- Magnum 340
- Magnum 370
- Magnum 380
- Steiger 350
- Steiger 400
- Steiger 450
- Steiger 500
- Steiger 550
- Steiger 600
- Quadtrac 350
- Quadtrac 400
- Quadtrac 450
- Quadtrac 500
- Quadtrac 550
- Quadtrac 600
- Puma 140
- Puma 150
- Puma 165
- Puma 185
- Puma 200
- Puma 220
- Puma 240
- Maxxum Series
- Optum Series
- Farmall Series
Check the cause
Visual Inspection for Scale: Remove the dosing injector and inspect the tip and the exhaust mixing chamber. Look for white scale deposits (crystallized urea). If scale is present, it prevents the vaporized DEF/AdBlue from mixing properly and blocks the valve.
Fluid Quality Check: Verify the DEF/AdBlue concentration. It should measure exactly 32.5% automotive-grade urea to 67.5% distilled water. If the concentration is incorrect, the fluid must be drained and replaced.
Electronic Service Tool (EST) Testing: Connect the EST and run a Urea Dosing System Test (UDST) to monitor the DEF pump pressure and speed.
Parameter Verification: During the UDST, verify that the DEF/AdBlue pressure does not exceed 500 kPa (5 bar) and the pump speed does not exceed 6000 RPM. If these measurements are abnormally high and no physical blockage exists, the internal DEF power module/pump is faulty.
Wiring Check: Ensure the electrical connectors between the dosing valve, pressure sensors, and the ECU are tight, undamaged, and free of corrosion.
Repair steps
Power Down
Turn off the machine and disconnect the battery to ensure the ECU is powered down.
Disconnect Electrical Harness
Locate the Urea Dosing Valve (UDV) on the exhaust system and disconnect its electrical harness connector.
Disconnect DEF Lines
Squeeze the locking tabs together on the DEF supply and return hoses and pull straight upward to disconnect them from the elbow. Cap all open fittings to prevent contamination.
Remove the Valve
Unbolt and remove the dosing valve from the exhaust mixing chamber.
Clean or Replace
If the mixing chamber is clogged with scale, clean it thoroughly. If the dosing valve is stuck closed or heavily scaled, replace it with a new unit.
Replace Supply Module (If necessary)
If the valve was not blocked but the EST test showed pressure >500 kPa or speed >6000 RPM, replace the NOx neutralization node (DEF supply module).
Reassembly
Install the new dosing valve, reconnect the DEF hoses (ensuring they click into place), and plug in the electrical harness.
Clear Codes and Test
Use the EST to clear the DCU/ECU fault codes. The engine must be brought to operating temperature and run under load until the ECU determines the SCR system is operating properly and the code does not return.
Parts you might need
(5)DEF Dosing Valve / Injector (UDV) for Magnum/Puma/Maxxum/Steiger
47565934DEF Dosing Valve / Injector (UDV) for Farmall Series
47581674Bosch OEM Equivalent Dosing Module
0 444 023 058Denoxtronic 2.2 Dosing Module
NOx Neutralization Node / DEF Supply Module
Generic part name; required if the pump itself is over-pressurizing the system
DEF / AdBlue Fluid
Standard 32.5% automotive-grade urea
Get help to fix this fault by requesting a quote