Case IH 19838 – Engine Control Module (ECM / ECU): SCG error on the Turbocharger PWM output powerstage
Issue description
The engine's control system uses a Pulse Width Modulation (PWM) signal to precisely control the turbocharger's wastegate actuator or boost pressure control solenoid. This fault code indicates that the control module has detected a short circuit to ground (SCG) on the electrical circuit (the 'output powerstage') that drives this turbocharger actuator.
Applies to these machines
17 machines- Tier 4b
- Magnum
- Steiger
- Puma
- Maxxum
- Farmall Pro series
- Farmall 100A Pro
- Farmall 120A Pro
- Farmall 150A Pro
- N-Series Tractor Loader Backhoes
- 580N
- 590SN
- heavy-duty wheel loaders
- T6
- T7
- T6000 series
- T7000 series
Check the cause
Visually inspect the engine wiring harness routing from the Engine ECU to the turbocharger wastegate actuator/solenoid for chafed insulation, melted wires, or pinch points touching the engine block or chassis.
Perform an Actuator Disconnect Test: Disconnect the electrical connector at the turbocharger PWM control valve/actuator, cycle the key, and see if the code changes to an Open Circuit (code 19835) to determine if the short is internal to the actuator.
Perform a Harness Continuity Test: With the battery disconnected and both the ECU and actuator unplugged, use a multimeter to check for continuity between the PWM signal wire and a known good chassis ground.
Inspect the ECU connector pins for water intrusion, bent pins, or corrosion that could bridge the PWM output pin to a ground pin.
Repair steps
Power Down
Turn off the machine, remove the key, and disconnect the negative battery cable.
Access the Turbocharger
Locate the turbocharger assembly and its attached electro-pneumatic boost control solenoid or electronic wastegate actuator.
Address Wiring (If Applicable)
If the diagnostic tests revealed a harness short, carefully open the wire loom, locate the bare wire shorting to the block, repair it with heat-shrink solder connectors, and re-loom the harness away from high-heat areas.
Replace the Actuator (If Applicable)
If the actuator is internally shorted: Disconnect the electrical connector. Remove the vacuum/pneumatic lines (if it is an electro-pneumatic valve) or unbolt the mechanical linkage (if it is a direct electronic actuator). Unbolt the actuator bracket and remove the faulty unit. Install the new OEM actuator, reconnect the linkage/hoses, and plug in the electrical connector.
Reassemble and Clear Codes
Reconnect the battery. Connect the CNH Electronic Service Tool (EST) or a compatible diagnostic scanner to clear the inactive 19838 fault code.
Test Run
Start the engine and run it under load to verify that turbocharger boost pressure is regulating correctly and the fault code does not return.
Parts you might need
(6)Electro-Pneumatic Turbocharger Boost Control Solenoid Valve (PWM Valve)
504385061Replaces older PN 504014902. Used heavily on Case IH Puma/Maxxum, New Holland T6/T7, and Case CE loaders. Features a 2-pin electrical socket and a 3-way micro hose barb configuration.
Electro-Pneumatic Turbocharger Boost Control Solenoid Valve (PWM Valve)
504014902Older part number, replaced by 504385061.
Electronic Wastegate Actuator (Direct)
J593678Used on larger displacement engines (e.g., Magnum MX210/MX230).
Electronic Wastegate Actuator (Direct) (Reman)
J593678RRemanufactured version of J593678.
Complete Turbocharger Assembly
5801361992On some smaller FPT engines (like the 4.5L NEF), the actuator is calibrated to the turbo and sold as a complete assembly (e.g., Garrett GT2556NS).
Complete Turbocharger Assembly
827729-5003Alternate part number for complete turbocharger assembly.