Case IH 19875 – Heater Control Unit (HCU): PRC high for voltage at DEF/AdBlue Supply module Heater (via HCU)

Issue description

The system has detected a voltage level that is higher than the expected range on the circuit responsible for heating the Diesel Exhaust Fluid (DEF) supply module (pump). This condition typically points to a short to voltage in the wiring harness, a failed internal heater element within the DEF supply module, or an internal failure of the Heater Control Unit itself.

Applies to these machines

  • Tier 4b
  • Magnum (180-370)
  • Maxxum (110-140)
  • Puma (130-215)
  • Steiger (350-600)
  • Vestrum
  • Farmall (95A, 100C, 110C)
  • Axial-Flow series (5130-9230)
  • Patriot
  • Titan sprayers
  • N Series Backhoe Loaders (e.g., 580SN)
  • Farmlift Telehandlers

Check the cause

  1. Inspect the wiring harness running from the HCU to the DEF Supply Module for chafing, melted insulation, or pinched wires that could cause a short to battery voltage.

  2. Disconnect the harness at the DEF Supply Module and the HCU. Check for corrosion, moisture (DEF fluid intrusion/crystallization), or bent pins.

  3. Measure the resistance of the DEF Supply Module Heater element pins to ensure it is within OEM specification and not internally shorted.

  4. Verify that the HCU is receiving proper voltage at Terminal 30 and has a clean ground connection.

Repair steps

  1. Disconnect Power

    Turn off the machine and disconnect the battery to prevent electrical spikes during the repair.

  2. Access the DEF Supply Module

    Locate the DEF supply module (pump), which is typically mounted directly to or near the DEF tank.

  3. Repair Wiring (If Applicable)

    If the diagnostic checks revealed a short to voltage in the harness, repair the damaged section of the wiring or replace the harness segment.

  4. Replace the DEF Supply Module (If Heater is Failed)

    Because the heater element is integrated into the DEF supply module on these Bosch Denoxtronic systems, a shorted heater requires replacing the entire supply module assembly. Disconnect the DEF fluid lines (suction, pressure, and backflow). Remove the mounting bolts and extract the old module. Install the new module, ensuring the surrounding area is completely clean of dried white urea crust to prevent contamination.

  5. Replace the HCU (If Module/Wiring Test Good)

    If the wiring is intact and the supply module heater tests within spec, the HCU has failed internally and must be replaced.

  6. Reassembly and Testing

    Reconnect the battery. Connect the Case IH EST to clear the 19875 fault code. Run a DEF system prime and dosing test via the EST to verify the heater circuit is operating within the correct voltage parameters.

Parts you might need

(9)
  • DEF Supply Module (Pump) Assembly

    84246892

    Fits most Magnum, Maxxum, Puma, and Steiger models

  • DEF Supply Module (Pump) Assembly

    47750812

    Fits Farmall 95A, 100C, 110C

  • DEF Supply Module (Pump) Assembly

    47662288

    Fits Farmall 95A, 100C, 110C

  • DEF Supply Module (Pump) Assembly

    47581676

    Fits Farmall 95A, 100C, 110C

  • Heater Control Unit (HCU)

    47392139

    Example fitment for 580SN / Tier 4B equipment

  • Heater Control Unit (HCU)

    55.050.010

    Example fitment for Vestrum/Farmall series

  • Heater Control Unit (HCU)

    55.202.AC[01]

    Example fitment for Vestrum/Farmall series

  • DEF Supply Module Filter

    48089821

    Recommended during pump service

  • DEF Supply Module Filter

    84367903

    Recommended during pump service

Get help to fix this fault by requesting a quote

Browse other Case IH codes